Literature DB >> 17470985

Tripolar Laplacian electrocardiogram and moment of activation isochronal mapping.

W Besio1, T Chen.   

Abstract

The electrocardiogram (ECG) provides useful global temporal assessment of the cardiac activity, but has limited spatial capabilities. The Laplacian electrocardiogram (LECG), an improvement over the ECG, provides high spatiotemporal distributed information about cardiac electrical activation. We designed and developed LECG tripolar concentric ring electrode active sensors based on the finite element algorithm 'nine-point method' (NPM). The active sensors were used in an array of 6 by 12 (72) locations to record bipolar and tripolar LECG from the body surface over the anterolateral chest. Compared to bipolar LECG, tripolar LECG showed significantly higher spatial selectivity which may be helpful in inferring information about cardiac activations detected on the body surface. In this study the moment of activation (MOA), an indicator of a depolarization wave passing below the active sensors, was used to surmise possible timing information of the cardiac electrical activation below the active sensors' recording sites. The MOA on the body surface was used to generate isochronal maps that may some day be used by clinicians in diagnosing arrhythmias and assessing the efficacy of therapies.

Entities:  

Mesh:

Year:  2007        PMID: 17470985     DOI: 10.1088/0967-3334/28/5/006

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  4 in total

1.  Textile Concentric Ring Electrodes for ECG Recording Based on Screen-Printing Technology.

Authors:  José Vicente Lidón-Roger; Gema Prats-Boluda; Yiyao Ye-Lin; Javier Garcia-Casado; Eduardo Garcia-Breijo
Journal:  Sensors (Basel)       Date:  2018-01-21       Impact factor: 3.576

2.  Evaluation of Bipolar, Tripolar, and Quadripolar Laplacian Estimates of Electrocardiogram via Concentric Ring Electrodes.

Authors:  Javier Garcia-Casado; Yiyao Ye-Lin; Gema Prats-Boluda; Oleksandr Makeyev
Journal:  Sensors (Basel)       Date:  2019-08-31       Impact factor: 3.576

3.  Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes.

Authors:  Oleksandr Makeyev; Walter G Besio
Journal:  Sensors (Basel)       Date:  2016-06-10       Impact factor: 3.576

4.  Solving the general inter-ring distances optimization problem for concentric ring electrodes to improve Laplacian estimation.

Authors:  Oleksandr Makeyev
Journal:  Biomed Eng Online       Date:  2018-08-30       Impact factor: 2.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.