Deformability of red blood cells and its relation to blood trauma in rotary blood pumps.

Nobuo Watanabe1, Daisuke Sakota, Katsuhiro Ohuchi, Setsuo Takatani.   

Abstract

In this study, mechanical trauma to red blood cells was evaluated by conventional hemolysis test and a newly developed cyclically reversing shear flow generator. The fresh porcine blood obtained from a local slaughterhouse was subjected to the conventional hemolysis test using a commercial centrifugal blood pump for the duration of 8 h. The measurements consisted of (i) plasma-free hemoglobin based on the standard optical measurement and (ii) the deformability of red blood cells (RBCs) using a cyclically reversing shear flow generator and microscope image acquisition system. The deformability of RBCs was expressed by the L/W value where L and W were the longer and shorter axes of the elongated RBCs' images. Although the plasma-free hemoglobin level increased with the pumping duration, the L/W remained unchanged for the duration of 8 h of pumping to indicate no alteration in the deformability. It was speculated that (i) although RBCs might have been circulated for so many times through the test pump, after each exposure to mechanical stress, RBCs might have recovered, and net effect due to shear stress-exposure time might have been small; and (ii) RBCs' deformability might be maintained near normal until sudden burst or membrane rupture, or the hemoglobin might have continuously leaked through the pores of the thinned membrane created by the mechanical stress. The deformability testing under a fluctuating shear flow could be a new method to quantify subhemolytic mechanical damage that has been accumulated in the RBCs' membrane and that may not be assessed by the conventional hemolysis test.

Entities:  

Mesh:

Year:  2007        PMID: 17470204     DOI: 10.1111/j.1525-1594.2007.00392.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  7 in total

1.  Application of drag-reducing polymer solutions as test fluids for in vitro evaluation of potential blood damage in blood pumps.

Authors:  Amanda R Daly; Hideo Sobajima; Salim E Olia; Setsuo Takatani; Marina V Kameneva
Journal:  ASAIO J       Date:  2010 Jan-Feb       Impact factor: 2.872

Review 2.  Hemolysis in cardiac surgery patients undergoing cardiopulmonary bypass: a review in search of a treatment algorithm.

Authors:  Leen Vercaemst
Journal:  J Extra Corpor Technol       Date:  2008-12

3.  Plasma Free Hemoglobin Is an Independent Predictor of Mortality among Patients on Extracorporeal Membrane Oxygenation Support.

Authors:  Hesham R Omar; Mehdi Mirsaeidi; Stephanie Socias; Collin Sprenker; Christiano Caldeira; Enrico M Camporesi; Devanand Mangar
Journal:  PLoS One       Date:  2015-04-22       Impact factor: 3.240

4.  Ex vivo lung perfusion to improve donor lung function and increase the number of organs available for transplantation.

Authors:  Franco Valenza; Lorenzo Rosso; Silvia Coppola; Sara Froio; Alessandro Palleschi; Davide Tosi; Paolo Mendogni; Valentina Salice; Giulia M Ruggeri; Jacopo Fumagalli; Alessandro Villa; Mario Nosotti; Luigi Santambrogio; Luciano Gattinoni
Journal:  Transpl Int       Date:  2014-04-04       Impact factor: 3.782

5.  Low-Level Light Therapy Protects Red Blood Cells Against Oxidative Stress and Hemolysis During Extracorporeal Circulation.

Authors:  Tomasz Walski; Anna Drohomirecka; Jolanta Bujok; Albert Czerski; Grzegorz Wąż; Natalia Trochanowska-Pauk; Michał Gorczykowski; Romuald Cichoń; Małgorzata Komorowska
Journal:  Front Physiol       Date:  2018-05-31       Impact factor: 4.566

6.  The impact of circulation in a heart-lung machine on function and survival characteristics of red blood cells.

Authors:  Joames Freitas Leal; Harry Vermeer; Dan Lazari; Leen van Garsse; Roland Brock; Merel Adjobo-Hermans; Giel Bosman
Journal:  Artif Organs       Date:  2020-04-03       Impact factor: 3.094

7.  Erythrocyte morphological symmetry analysis to detect sublethal trauma in shear flow.

Authors:  Antony P McNamee; Michael J Simmonds; Masataka Inoue; Jarod T Horobin; Masaya Hakozaki; John F Fraser; Nobuo Watanabe
Journal:  Sci Rep       Date:  2021-12-07       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.