Literature DB >> 17468569

Electrical impedance tomography guided ventilation therapy.

Christian Putensen1, Hermann Wrigge, Jörg Zinserling.   

Abstract

PURPOSE OF REVIEW: Computed tomography (CT) in patients with acute respiratory distress syndrome has shown that intrapulmonary gas is not homogeneously distributed. Although regional ventilation can be studied by isotope and magnetic resonance techniques while aeration of the lungs can be imaged using CT, these techniques are not available at the bedside. Recently, electrical impedance tomography has been introduced as a true bedside technique which provides information on regional ventilation distribution. RECENT
FINDINGS: Electrical impedance tomography can reliably determine regional ventilation in healthy lungs and various models of induced lung injury when compared with CT, electron beam CT, and single photon emission CT. In healthy volunteers and patients with acute lung injury, relative impedance changes on the electrical impedance tomography image demonstrate an excellent correlation with regional changes in lung air content detected by CT. In a limited number of patients with respiratory dysfunction, gas exchange was found to improve when electrical impedance tomography was used to adjust ventilator settings, improving regional ventilation and avoiding tidal alveolar collapse.
SUMMARY: In view of recently published data, it can be concluded that, in critically ill patients, electrical impedance tomography determines reliable regional ventilation. Therefore, this technique has the potential to become a valuable bedside tool.

Entities:  

Mesh:

Year:  2007        PMID: 17468569     DOI: 10.1097/MCC.0b013e328136c1e2

Source DB:  PubMed          Journal:  Curr Opin Crit Care        ISSN: 1070-5295            Impact factor:   3.687


  21 in total

1.  Evaluation of an electrical impedance tomography-based Global Inhomogeneity Index for pulmonary ventilation distribution.

Authors:  Zhanqi Zhao; Knut Möller; Daniel Steinmann; Inéz Frerichs; Josef Guttmann
Journal:  Intensive Care Med       Date:  2009-08-04       Impact factor: 17.440

Review 2.  Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?

Authors:  Steffen Leonhardt; Burkhard Lachmann
Journal:  Intensive Care Med       Date:  2012-09-20       Impact factor: 17.440

Review 3.  Electrical impedance tomography.

Authors:  Beatriz Lobo; Cecilia Hermosa; Ana Abella; Federico Gordo
Journal:  Ann Transl Med       Date:  2018-01

Review 4.  [Extreme obesity-particular aspect of invasive and noninvasive ventilation].

Authors:  M Deppe; P Lebiedz
Journal:  Med Klin Intensivmed Notfmed       Date:  2017-09-05       Impact factor: 0.840

5.  Distribution of tidal ventilation during volume-targeted ventilation is variable and influenced by age in the preterm lung.

Authors:  Ruth K Armstrong; Hazel R Carlisle; Peter G Davis; Andreas Schibler; David G Tingay
Journal:  Intensive Care Med       Date:  2011-02-25       Impact factor: 17.440

6.  Absolute electrical impedance tomography (aEIT) guided ventilation therapy in critical care patients: simulations and future trends.

Authors:  Mouloud A Denaï; Mahdi Mahfouf; Suzani Mohamad-Samuri; George Panoutsos; Brian H Brown; Gary H Mills
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-11-10

7.  PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography.

Authors:  Zhanqi Zhao; Daniel Steinmann; Inéz Frerichs; Josef Guttmann; Knut Möller
Journal:  Crit Care       Date:  2010-01-30       Impact factor: 9.097

Review 8.  Brazilian recommendations of mechanical ventilation 2013. Part I.

Authors: 
Journal:  J Bras Pneumol       Date:  2014 Jul-Aug       Impact factor: 2.624

9.  Lung regions identified with CT improve the value of global inhomogeneity index measured with electrical impedance tomography.

Authors:  Lin Yang; Meng Dai; Knut Möller; Inéz Frerichs; Andy Adler; Feng Fu; Zhanqi Zhao
Journal:  Quant Imaging Med Surg       Date:  2021-04

10.  Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels.

Authors:  Ido G Bikker; Steffen Leonhardt; Jan Bakker; Diederik Gommers
Journal:  Intensive Care Med       Date:  2009-06-10       Impact factor: 17.440

View more