Literature DB >> 17467627

On the accuracy of CartoMerge for guiding posterior left atrial ablation in man.

Hua Zhong1, Joan M Lacomis, David Schwartzman.   

Abstract

BACKGROUND: Recent reports suggest that the CartoMerge system is useful for guiding human posterior left atrial (PLA) endocardial ablation.
OBJECTIVE: To assess the accuracy of the CartoMerge system during PLA ablation.
METHODS: Sixteen patients undergoing PLA catheter ablation were studied. In each patient, registration of preoperative computed tomographic (CT) and intraoperative electroanatomic left atrial images was performed to create CartoMerge images. Encircling of right and left pulmonary venous vestibules with ablation points was then performed guided solely by intracardiac echocardiography, with point locations saved on a CartoMerge image to which the operator was blinded. The accuracy of the CartoMerge image was then assessed by measuring the distance from the location of each ablation point on the image to its actual anatomic location. In five patients, accuracy of registration of each of three left atrial CT images (just prior to mitral valve opening, at end-diastasis, at end-atrial contraction) with the electroanatomic image was compared. In two patients, accuracy of registration using left atrial image data alone was compared with that which used both left atrial and thoracic aorta image data.
RESULTS: In each patient, inaccuracy of the CartoMerge image was apparent, the magnitude of which was similar for right- and left-vestibule ablation points. Accuracy was significantly improved when the end-atrial contraction CT image was used for registration. The inclusion of thoracic aorta image data did not improve accuracy.
CONCLUSIONS: The CartoMerge system is inaccurate. Inaccuracy may be reduced by using CT and electroanatomic images obtained at the same point in the atrial mechanical cycle.

Entities:  

Mesh:

Year:  2007        PMID: 17467627     DOI: 10.1016/j.hrthm.2007.01.033

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  28 in total

Review 1.  Fusion of imaging technologies: how, when, and for whom?

Authors:  Ashul Govil; Hugh Calkins; David D Spragg
Journal:  J Interv Card Electrophysiol       Date:  2011-10-01       Impact factor: 1.900

2.  Experience with CartoSound for arrhythmia ablation in pediatric and congenital heart disease patients.

Authors:  Adam C Kean; Sarah K Gelehrter; Ira Shetty; Macdonald Dick; David J Bradley
Journal:  J Interv Card Electrophysiol       Date:  2010-09-28       Impact factor: 1.900

3.  Left Atrial Image Registration to Guide Catheter Ablation of Atrial Fibrillation: In the Eye of the Technology.

Authors:  Ósmar Antonio Centurión
Journal:  J Atr Fibrillation       Date:  2008-09-16

4.  Characterizing Conduction Channels in Postinfarction Patients Using a Personalized Virtual Heart.

Authors:  Dongdong Deng; Adityo Prakosa; Julie Shade; Plamen Nikolov; Natalia A Trayanova
Journal:  Biophys J       Date:  2019-07-22       Impact factor: 4.033

Review 5.  Imaging-Based Simulations for Predicting Sudden Death and Guiding Ventricular Tachycardia Ablation.

Authors:  Natalia A Trayanova; Farhad Pashakhanloo; Katherine C Wu; Henry R Halperin
Journal:  Circ Arrhythm Electrophysiol       Date:  2017-07

Review 6.  Cardiac Image Registration.

Authors:  Jasbir Sra
Journal:  J Atr Fibrillation       Date:  2008-09-16

Review 7.  The Role of Atrial Structural Remodeling in Atrial Fibrillation Ablation:An Imaging Point of View for Predicting Recurrence.

Authors:  Yasushi Akutsu; Kaoru Tanno; Youichi Kobayashi
Journal:  J Atr Fibrillation       Date:  2012-08-20

8.  Intracardiac ECHO Integration with Three Dimensional Mapping: Role in AF Ablation.

Authors:  Yaariv Khaykin; Allan Skanes; Zaev A Wulffhart; Lorne Gula; Bonnie Whaley; Richard Oosthuizen; Catherine Seabrook; Marianne Beardsall; Atul Verma
Journal:  J Atr Fibrillation       Date:  2008-07-16

9.  Identification of left atrial fibrosis with a late-enhancement MR sequence (LE-MR): preliminary results.

Authors:  Giulia Casagranda; Elena Costanza dal Piaz; Daniele Ravanelli; Maurizio Del Greco; Massimiliano Marini; Aldo Valentini; Maurizio Centonze
Journal:  Radiol Med       Date:  2013-12-03       Impact factor: 3.469

10.  Feasibility of real-time magnetic resonance imaging for catheter guidance in electrophysiology studies.

Authors:  Saman Nazarian; Aravindan Kolandaivelu; Menekhem M Zviman; Glenn R Meininger; Ritsushi Kato; Robert C Susil; Ariel Roguin; Timm L Dickfeld; Hiroshi Ashikaga; Hugh Calkins; Ronald D Berger; David A Bluemke; Albert C Lardo; Henry R Halperin
Journal:  Circulation       Date:  2008-06-23       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.