Literature DB >> 17466887

In vitro perception of low-contrast features in digital, film, and digitized dental radiographs: a receiver operating characteristic analysis.

Ulrich Grassl1, Ralf Kurt Willy Schulze.   

Abstract

OBJECTIVE: To compare experimentally the image quality of charged-coupled device (CCD)-based digital, flatbed scanner digitized, and dental film radiographs. STUDY
DESIGN: High-contrast standardized radiographs of an aluminum step wedge containing boreholes were obtained on dental radiographic film (F) and a CCD receptor (D). Digitization (S) was done with a flatbed scanner. Each radiograph was separated into 23 single images, 18 of which showed a dark spot. Thirty observers indicated their confidence on the visibility of the spots for a receiver operating characteristic (ROC) analysis.
RESULTS: Mean Az values (area beneath the ROC curves) differed significantly (P < .05), being highest for D (Az = 0.76), followed by F (Az = 0.71) and S (Az = 0.60). Mean sensitivity of S (0.45) was significantly (P = .000) lower than for D (0.66) and F (0.67).
CONCLUSION: The difference between modality D and F was small. However, the inferior performance of S images, particularly in dark regions, could be clinically relevant.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17466887     DOI: 10.1016/j.tripleo.2006.04.005

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  6 in total

1.  The influence of ambient lighting on the detection of small contrast elements in digital dental radiographs.

Authors:  Till Schriewer; Ralf Schulze; Andreas Filippi; Irene Mischak; Michael Payer; Dorothea Dagassan-Berndt; Sebastian Kühl
Journal:  Clin Oral Investig       Date:  2012-10-07       Impact factor: 3.573

2.  Detection of dental root fractures by using cone-beam computed tomography.

Authors:  P Wang; X B Yan; D G Lui; W L Zhang; Y Zhang; X C Ma
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

3.  A comparative study on image quality of two digital intraoral sensors.

Authors:  Cinar Aziman; Kristina Hellén-Halme; Xie-Qi Shi
Journal:  Dentomaxillofac Radiol       Date:  2019-05-14       Impact factor: 2.419

4.  Influence of the display monitor on observer performance in detection of dental caries.

Authors:  Farzad Esmaeili; Esrafil Balaei; Firoz Pouralibaba; Farzaneh Kaviani; Atabak Kashefimehr
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2007-09-10

5.  Application of Fractal Analysis in Detecting Trabecular Bone Changes in Periapical Radiograph of Patients with Periodontitis.

Authors:  Parisa Soltani; Sajad Sami; Jaber Yaghini; Ehsan Golkar; Francesco Riccitiello; Gianrico Spagnuolo
Journal:  Int J Dent       Date:  2021-10-07

6.  Impact of viewing conditions on the performance assessment of different computer monitors used for dental diagnostics.

Authors:  Thomas Hastie; Sascha Venske-Parker; Johan K M Aps
Journal:  Imaging Sci Dent       Date:  2021-02-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.