Thermal analysis of as-received and clinically retrieved copper-nickel-titanium orthodontic archwires.

Matthew C Biermann1, David W Berzins, Thomas Gerard Bradley.   

Abstract

OBJECTIVE: To compare as-received copper-nickel-titanium (CuNiTi) archwires to those used in patients by means of differential scanning calorimetry (DSC). Also, the thermal or phase properties of 27 degrees C, 35 degrees C, and 40 degrees C CuNiTi archwires were studied to ascertain if their properties match those indicated by the manufacturer.
MATERIALS AND METHODS: Six wires of 27 degrees C, 35 degrees C, and 40 degrees C CuNiTi were tested as-received, and six each of the 27 degrees C and 35 degrees C wires were examined after use in patients for an average of approximately 9 and 7 weeks, respectively. Segments of archwire were investigated by DSC over the temperature range from -100 degrees C to 150 degrees C at 10 degrees C per minute.
RESULTS: There were no significant differences between as-received and clinically used 27 degrees C and 35 degrees C wires for all parameters (heating onset, endset, and enthalpy and cooling onset, endset, and enthalpy), except the 27 degrees C wires exhibited a significant decrease in the heating enthalpy associated with the martensite-to-austenite transition after clinical use. The heating endsets (austenite finish temperatures) of the 27 degrees C and 35 degrees C wires were within 2 degrees C of those claimed by the manufacturer, but the 40 degrees C wires were found to be nearer to 36 degrees C than 40 degrees C.
CONCLUSIONS: Clinical use of CuNiTi wires resulted in few differences when compared with as-received wires analyzed by DSC. Two temperature varieties of CuNiTi are reasonably within the parameters of those identified by the manufacturer.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17465660     DOI: 10.2319/0003-3219(2007)077[0499:TAOAAC]2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  3 in total

1.  Transition temperature range of thermally activated nickel-titanium archwires.

Authors:  Tatiana Sobottka Spini; Fabricio Pinelli Valarelli; Rodrigo Hermont Cançado; Karina Maria Salvatore de Freitas; Denis Jardim Villarinho
Journal:  J Appl Oral Sci       Date:  2014-04       Impact factor: 2.698

2.  Corrosion resistance of surface modified nickel titanium archwires.

Authors:  Manu Krishnan; Saraswathy Seema; A Vinod Kumar; N Parvatha Varthini; Kalathil Sukumaran; Vasant R Pawar; Vimal Arora
Journal:  Angle Orthod       Date:  2013-09-04       Impact factor: 2.079

3.  Effect of Recycling and Autoclave Sterilization on the Unloading Forces of NiTi Closed-Coil Springs: An In Vitro Study.

Authors:  Sh Momeni Danaei; M Oshagh; A Khozaei
Journal:  J Dent (Shiraz)       Date:  2013-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.