Literature DB >> 17463127

Metal ion levels in a triathlete with a metal-on-metal resurfacing arthroplasty of the hip.

R De Haan1, P Campbell, S Reid, A K Skipor, K De Smet.   

Abstract

A prospective study of serum and urinary ion levels was undertaken in a triathlete who had undergone a metal-on-metal resurfacing arthroplasty of the hip four years previously. The one month study period included the final two weeks of training, the day of the triathlon, and the two weeks immediately post-race. Serum cobalt and chromium levels did not vary significantly throughout this period, including levels recorded on the day after the 11-hour triathlon. Urinary excretion of chromium increased immediately after the race and had returned to pre-race levels six days later. The clinical implications are discussed.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17463127     DOI: 10.1302/0301-620X.89B4.18563

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  8 in total

Review 1.  [Implant wear and aseptic loosening. An overview].

Authors:  C Kaddick; I Catelas; P H Pennekamp; M A Wimmer
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

Review 2.  Hip replacement in the athlete: is there a role?

Authors:  M J Wilson; R N Villar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-12       Impact factor: 4.342

3.  Insufficient acetabular version increases blood metal ion levels after metal-on-metal hip resurfacing.

Authors:  Alister J Hart; John A Skinner; Johann Henckel; Barry Sampson; Fabiana Gordon
Journal:  Clin Orthop Relat Res       Date:  2011-06-09       Impact factor: 4.176

4.  No association between pseudotumors, high serum metal-ion levels and metal hypersensitivity in large-head metal-on-metal total hip arthroplasty at 5-7-year follow-up.

Authors:  Mette Holm Hjorth; Maiken Stilling; Kjeld Soballe; Lars Hans Bolvig; Jacob Pontoppidan Thyssen; Inger Mechlenburg; Stig Storgaard Jakobsen
Journal:  Skeletal Radiol       Date:  2015-10-10       Impact factor: 2.199

5.  Contact patch to rim distance predicts metal ion levels in hip resurfacing.

Authors:  James P Yoon; Michel J Le Duff; Alicia J Johnson; Karren M Takamura; Edward Ebramzadeh; Harlan C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2012-11-27       Impact factor: 4.176

6.  Return to Sport After Hip Resurfacing Arthroplasty.

Authors:  Kyle W Morse; Ajay Premkumar; Andrew Zhu; Rachelle Morgenstern; Edwin P Su
Journal:  Orthop J Sports Med       Date:  2021-05-06

7.  Blood metal ion testing is an effectivescreening tool to identify poorly performing metal-on-metal bearingsurfaces.

Authors:  R P Sidaginamale; T J Joyce; J K Lord; R Jefferson; P G Blain; A V F Nargol; D J Langton
Journal:  Bone Joint Res       Date:  2013-05-16       Impact factor: 5.853

8.  The correlation between activity level, serum-ion concentrations and pseudotumours in patients with metal-on-metal hip articulations and metal-on-polyethylene total hip articulations.

Authors:  Mette Holm Hjorth; Inger Mechlenburg; Kjeld Soballe; Lone Roemer; Maiken Stilling
Journal:  J Orthop Translat       Date:  2018-12-17       Impact factor: 5.191

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.