Literature DB >> 17462876

Electrochemical detection of cardiac troponin I using a microchip with the surface-functionalized poly(dimethylsiloxane) channel.

Sungho Ko1, Bumjun Kim, Seong-Sik Jo, Se Young Oh, Je-Kyun Park.   

Abstract

A sensitive and rapid electrochemical microchip fabricated by assembling a surface-functionalized poly(dimethylsiloxane) (PDMS) microchannel with an interdigitated array (IDA) gold electrode was developed for the detection of human cardiac troponin I (cTnI) in the early diagnosis of acute myocardial infarction. Anti-cTnI was immobilized onto the internal surface of the PDMS channel on which protein G layer had been generated by silanization. To reduce electrode fouling, a PDMS channel was assembled with an IDA chip after surface treatment. The detection experiments were performed with successive injection of cTnI, alkaline phosphatase (AP)-labeled anti-cTnI, and p-aminophenylphosphate. Then, cyclic voltammograms were obtained by the oxidation peak current proportionally to the concentration of enzymatic product, p-aminophenol. The optimal packing density of anti-cTnI on the surface of the PDMS channel was determined at the anti-cTnI concentration of 30 microg/ml for the highest electrochemical signal. These demonstrate that the proper orientation and best packing density of antibody as well as no electrode fouling contributed to the low detection limit (148 pg/ml) of cTnI within 8 min.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17462876     DOI: 10.1016/j.bios.2007.03.013

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  A Novel Electrochemical Microfluidic Chip Combined with Multiple Biomarkers for Early Diagnosis of Gastric Cancer.

Authors:  Yao Xie; Xiao Zhi; Haichuan Su; Kan Wang; Zhen Yan; Nongyue He; Jingpu Zhang; Di Chen; Daxiang Cui
Journal:  Nanoscale Res Lett       Date:  2015-12-10       Impact factor: 4.703

2.  Electrochemical Impedance Analysis of Biofunctionalized Conducting Polymer-Modified Graphene-CNTs Nanocomposite for Protein Detection.

Authors:  Shobhita Singal; Avanish K Srivastava
Journal:  Nanomicro Lett       Date:  2016-09-15

3.  A self-assembled fusion protein-based surface plasmon resonance biosensor for rapid diagnosis of severe acute respiratory syndrome.

Authors:  Tae Jung Park; Moon Seop Hyun; Hye Jin Lee; Sang Yup Lee; Sungho Ko
Journal:  Talanta       Date:  2009-04-01       Impact factor: 6.057

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.