Literature DB >> 17462129

On-line SPE-Nano-LC-Nanospray-MS for rapid and sensitive determination of perfluorooctanoic acid and perfluorooctane sulfonate in river water.

Steven Ray Wilson1, Helle Malerød, Anders Holm, Paal Molander, Elsa Lundanes, Tyge Greibrokk.   

Abstract

An instrumental set up including on-line solid-phase extraction, nano-liquid chromatography, and nanospray mass spectrometry is constructed to improve the sensitivity for quantitation of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in surface water. Sample volumes of 1000 microL are loaded onto a microbore 1.0-mm i.d. x 5 mm, 5 microm Kromasil C(18) enrichment column by a carrier solution consisting of 10mM ammonium acetate in acetonitrile-water (10:90, v/v) at a flow rate of 250 microL/min, providing on-line analyte enrichment and sample clean-up. Backflushed elution onto a 0.1-mm i.d. x 150 mm, 3.5 microm Kromasil C(18) analytical column is conducted using an acetonitrile-10mM ammonium acetate solvent gradient from 30% to 70% acetonitrile. Water samples are added with internal standard (perfluoroheptanoic acid) and filtrated prior to injection. The mass limits of detection of PFOA and PFOS are 0.5 and 1 pg, respectively, corresponding to concentration limits of detection of 500 pg/L and 1 ng/L, respectively. The total time spent on sample preparation, chromatography, and detection is approximately 12 min per sample. The method was employed for the determination of PFOS and PFOA in urban river water.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17462129     DOI: 10.1093/chromsci/45.3.146

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618


  3 in total

1.  An on-line solid phase extraction-liquid chromatography-tandem mass spectrometry method for the determination of perfluoroalkyl acids in drinking and surface waters.

Authors:  Michela Mazzoni; Marianna Rusconi; Sara Valsecchi; Claudia P B Martins; Stefano Polesello
Journal:  J Anal Methods Chem       Date:  2015-03-05       Impact factor: 2.193

2.  Liquid chromatography-tandem mass spectrometry analysis of perfluorooctane sulfonate and perfluorooctanoic Acid in fish fillet samples.

Authors:  Viviana Paiano; Elena Fattore; Andrea Carrà; Caterina Generoso; Roberto Fanelli; Renzo Bagnati
Journal:  J Anal Methods Chem       Date:  2012-03-18       Impact factor: 2.193

3.  Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring.

Authors:  Hanne Roberg-Larsen; Silvija Abele; Deniz Demir; Diana Dzabijeva; Sunniva F Amundsen; Steven R Wilson; Vadims Bartkevics; Elsa Lundanes
Journal:  Front Chem       Date:  2017-08-28       Impact factor: 5.221

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.