Literature DB >> 17462116

Perioperative feasibility of imaging the heart and pleura in patients with aortic stenosis undergoing aortic valve replacement.

C-J Jakobsen1, P Torp, E Sloth.   

Abstract

BACKGROUND: The postoperative monitoring and treatment of the patient undergoing aortic valve replacement is a complex challenge. Echocardiography is the only method which provides dynamic and real-time bedside imaging of the heart. Focused assessed transthoracic echocardiography has been shown to provide a usable window for cardiac imaging in a mixed ICU population. The aim of this study was to evaluate the feasibility of perioperative imaging of the heart and pleura according to the focused assessed transthoracic echocardiography protocol in patients scheduled for aortic valve replacement.
METHOD: Thirty-five adult patients scheduled for aortic valve replacement were followed perioperatively with focused assessed transthoracic echocardiography examinations. A Vivid-7 echo-machine and a 2.5 MHz matrix transducer with second-harmonic imaging were used for data acquisition. The image quality for the cardiac window was graded 1-5 (1 = no image, 2 = poor and unusable image quality, 3 = usable image quality, 4 = good image quality and 5 = perfect image quality). A score >or=3 equalled an image quality judged to be of sufficient quality to be interpreted and thereby to contribute to clinical decision-making.
RESULTS: All patients had at least one usable window preoperatively. At least one usable window was obtained in 88% of patients on the first postoperative day, and in 97% at discharge. The image quality changed over time, with the poorest quality being observed on the first postoperative day. The apical view with the patient in the left lateral position provided the best cardiac window on all occasions. The presence of drains did not significantly affect the achievability of a satisfactory examination. The number of patients with pleural effusion was relatively high. On the first postoperative day, 10 subjects had unilateral and one subject had bilateral pleural effusions. At discharge, 14 patients had unilateral and four patients had bilateral effusions.
CONCLUSIONS: We conclude that the image quality of the heart and pleura, according to the focused assessed transthoracic echocardiography concept, is sufficient to undergo interpretation and thereby contribute to the perioperative clinical decision-making in patients with aortic stenosis.

Entities:  

Mesh:

Year:  2007        PMID: 17462116     DOI: 10.1017/S0265021507000348

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  10 in total

1.  Point-of-Care Clinical Ultrasound for Medical Students.

Authors:  J Heiberg; L S Hansen; K Wemmelund; A H Sørensen; C Ilkjaer; E Cloete; D Nolte; F Roodt; R Dyer; J Swanevelder; E Sloth
Journal:  Ultrasound Int Open       Date:  2015-11-06

2.  Assessing left ventricular systolic function in shock: evaluation of echocardiographic parameters in intensive care.

Authors:  Lill Bergenzaun; Petri Gudmundsson; Hans Öhlin; Joachim Düring; Anders Ersson; Lilian Ihrman; Ronnie Willenheimer; Michelle S Chew
Journal:  Crit Care       Date:  2011-08-16       Impact factor: 9.097

3.  Echocardiographic Measures of Diastolic Function Are Preload Dependent during Triggered Positive Pressure Ventilation: A Controlled Crossover Study in Healthy Subjects.

Authors:  Peter Juhl-Olsen; Christian Alcaraz Frederiksen; Johan Fridolf Hermansen; Carl-Johan Jakobsen; Erik Sloth
Journal:  Crit Care Res Pract       Date:  2012-09-25

4.  Longitudinal evaluation the pulmonary function of the pre and postoperative periods in the coronary artery bypass graft surgery of patients treated with a physiotherapy protocol.

Authors:  Adalgiza M Moreno; Renata R T Castro; Pedro P S Sorares; Mauricio Sant' Anna; Sergio L d Cravo; Antônio C L Nóbrega
Journal:  J Cardiothorac Surg       Date:  2011-04-27       Impact factor: 1.637

5.  Does physician experience influence the interpretability of focused echocardiography images performed by a pocket device?

Authors:  Xavier Bobbia; Christophe Pradeilles; Pierre Géraud Claret; Camille Soullier; Patricia Wagner; Yann Bodin; Claire Roger; Guillaume Cayla; Laurent Muller; Jean Emmanuel de La Coussaye
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2015-07-07       Impact factor: 2.953

6.  Assessment of cardiac pathology by point-of-care ultrasonography performed by a novice examiner is comparable to the gold standard.

Authors:  Christian Alcaraz Frederiksen; Peter Juhl-Olsen; Niels Holmark Andersen; Erik Sloth
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2013-12-13       Impact factor: 2.953

7.  Offshore telementored ultrasound: a quality assessment study.

Authors:  Victoria Vatsvåg; Kjetil Todnem; Torvind Næsheim; John Cathcart; Daniel Kerr; Nils Petter Oveland
Journal:  Ultrasound J       Date:  2020-07-02

8.  Evaluation of volume responsiveness by pulse pressure variability and inferior vena cava dispensability index at different tidal volumes by mechanical ventilation.

Authors:  Fujuan He; Xiaoqiang Li; Suman Thapa; Chi Li; Jiawei Luo; Wenyan Dai; Jin Liu
Journal:  Braz J Med Biol Res       Date:  2019-08-29       Impact factor: 2.590

9.  Feasibility Evaluation of Commercially Available Video Conferencing Devices to Technically Direct Untrained Nonmedical Personnel to Perform a Rapid Trauma Ultrasound Examination.

Authors:  Davinder Ramsingh; Michael Ma; Danny Quy Le; Warren Davis; Mark Ringer; Briahnna Austin; Cameron Ricks
Journal:  Diagnostics (Basel)       Date:  2019-11-14

10.  Limited intervention improves technical skill in focus assessed transthoracic echocardiography among novice examiners.

Authors:  Christian Alcaraz Frederiksen; Peter Juhl-Olsen; Dorte Guldbrand Nielsen; Berit Eika; Erik Sloth
Journal:  BMC Med Educ       Date:  2012-08-03       Impact factor: 2.463

  10 in total