NARCOBIT: a newly developed inhalational anesthesia system for mice.

Yoshikazu Matsuda1, Kazumasa Ohsaka, Hidekazu Yamamoto, Kouzou Jiyouraku, Katsuhiko Natsume, Shirokazu Hirabayashi, Masayoshi Kounoike, Masaaki Inoue.   

Abstract

NARCOBIT is the first anesthetic system for mice and rats to incorporate a ventilator. Therefore, it is expected to improve the reliability of mice and rat experiments by accurately controlling and maintaining the depth of anesthesia. In this study, we used NARCOBIT for inducing inhalational anesthesia in mice and evaluated the changes in their hemodynamic parameters. ICR mice were anesthetized with 5% isoflurane and room air, followed by endotracheal intubation. Subsequently, they were mechanically ventilated, and anesthesia was maintained by 2% isoflurane for a 60-min period (maintenance state) using NARCOBIT. In study 1, the heart rate (HR) and mean arterial blood pressure (MAP) were measured. The skin blood flow (SBF) from the hind legs was continuously measured during the maintenance state. Subsequently, the concentration-dependent effects of isoflurane on MAP were examined. In study 2, blood samples were obtained from the abdominal aorta for blood gas analysis. The HR and MAP decreased after anesthesia but were stable during the maintenance state. Decreased MAP and concentration-dependent effects of isoflurane were observed. The SBF increased slightly during the maintenance state but this increase was insignificant. The blood gas analysis showed neither hypoxia nor hypercapnia. Since the use of NARCOBIT enables the anesthetic concentration of isoflurane to be easily changed, a suitable anesthesia depth can be obtained for experimental purposes. Therefore, we conclude that NARCOBIT can be used for providing inhalational anesthesia to mice.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17460358     DOI: 10.1538/expanim.56.131

Source DB:  PubMed          Journal:  Exp Anim        ISSN: 0007-5124


  5 in total

1.  Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents.

Authors:  Krista Bigiarelli; Luke E Schepers; Arvin H Soepriatna; Dave FitzMiller; Craig J Goergen
Journal:  J Vis Exp       Date:  2020-07-09       Impact factor: 1.355

2.  Effects of isoflurane anesthesia on the cardiovascular function of the C57BL/6 mouse.

Authors:  Christakis Constantinides; Richard Mean; Ben J Janssen
Journal:  ILAR J       Date:  2011

3.  Use of a Low-flow Digital Anesthesia System for Mice and Rats.

Authors:  Amelia R Adelsperger; Krista J Bigiarelli-Nogas; Irina Toore; Craig J Goergen
Journal:  J Vis Exp       Date:  2016-09-07       Impact factor: 1.355

4.  More effective induction of anesthesia using midazolam-butorphanol-ketamine-sevoflurane compared with ketamine-sevoflurane in the common marmoset monkey (Callithrix jacchus).

Authors:  Hidetoshi Ishibashi
Journal:  J Vet Med Sci       Date:  2015-09-11       Impact factor: 1.267

Review 5.  Molecular and Integrative Physiological Effects of Isoflurane Anesthesia: The Paradigm of Cardiovascular Studies in Rodents using Magnetic Resonance Imaging.

Authors:  Christakis Constantinides; Kathy Murphy
Journal:  Front Cardiovasc Med       Date:  2016-07-29