Morphometry of the retrobulbar human optic nerve: comparison between conventional sonography and ultrafast magnetic resonance sequences.

Wolf A Lagrèze1, Alexander Lazzaro, Matthias Weigel, Hans-Christian Hansen, Jürgen Hennig, Thorsten A Bley.   

Abstract

PURPOSE: To compare different methods for quantification of optic nerve and nerve sheath diameter. To apply a novel magnetic resonance protocol using half-Fourier acquired single-shot turbo spin-echo (HASTE) sequences to analyze optic nerve dimensions.
METHODS: Measurements were taken in right eyes of 33 subjects whose median age was 25 years. A-scan ultrasonography was repeated three times in straight gaze. B-scan ultrasonography was repeated three times in straight gaze and abduction. HASTE sequences were applied in straight gaze, analyzed twice by two different radiologists, and completely repeated in a subset of 10 subjects; 95% confidence intervals and coefficients of variation were calculated.
RESULTS: HASTE sequences yielded high contrast between cerebrospinal fluid and optic nerve parenchyma. Acquisition time for each sequence was 1.5 seconds per slice. Optic nerve diameters decreased from 3.23 mm at 5 mm to 2.67 mm at 15 mm behind the eye. Sheath diameters decreased from 5.72 mm to 3.98 mm. A- and B-scan ultrasonography yielded significantly smaller diameters. For HASTE sequences, the coefficients of variation ranged from 2% to 7% and were significantly smaller than those obtained with ultrasonographic measurements (9%-13%).
CONCLUSIONS: The precision of magnetic resonance imaging exceeds that of ultrasonographic methods for determining optic nerve and nerve sheath diameters. HASTE sequences appear particularly appropriate for investigating the retrobulbar optic nerve complex and may be useful in future studies quantifying axonal loss within the optic nerve.

Entities:  

Mesh:

Year:  2007        PMID: 17460241     DOI: 10.1167/iovs.06-1075

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  20 in total

1.  Non-invasive methods of estimating intracranial pressure.

Authors:  Jamie B Rosenberg; Ariel L Shiloh; Richard H Savel; Lewis A Eisen
Journal:  Neurocrit Care       Date:  2011-12       Impact factor: 3.210

2.  Transorbital sonographic measurement of normal optic sheath nerve diameter in nigerian adult population.

Authors:  Ismail Anas
Journal:  Malays J Med Sci       Date:  2014 Sep-Oct

Review 3.  MR imaging of papilledema and visual pathways: effects of increased intracranial pressure and pathophysiologic mechanisms.

Authors:  N Passi; A J Degnan; L M Levy
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-15       Impact factor: 3.825

4.  Comparison of Two Techniques to Measure Optic Nerve Sheath Diameter in Patients at Risk for Increased Intracranial Pressure.

Authors:  Ashish Agrawal; Roger Cheng; Julin Tang; Debbie Y Madhok
Journal:  Crit Care Med       Date:  2019-06       Impact factor: 7.598

5.  High resolution transbulbar sonography in children with suspicion of increased intracranial pressure.

Authors:  Marc Steinborn; Melanie Friedmann; Christine Makowski; Helmut Hahn; Alexander Hapfelmeier; Hendrik Juenger
Journal:  Childs Nerv Syst       Date:  2016-01-13       Impact factor: 1.475

Review 6.  [Indications and technique for transconjunctival optic nerve sheath fenestration : Video article].

Authors:  W A Lagrèze; N Gross; J Biermann; L Joachimsen
Journal:  Ophthalmologe       Date:  2017-10       Impact factor: 1.059

7.  Size of the intracranial optic nerve and optic tract in neonates at term-equivalent age at magnetic resonance imaging.

Authors:  Jun Oyama; Kouichi Mori; Masatoshi Imamura; Yukiko Mizushima; Ukihide Tateishi
Journal:  Pediatr Radiol       Date:  2015-12-08

8.  Estimation of optic nerve sheath diameter on an initial brain computed tomography scan can contribute prognostic information in traumatic brain injury patients.

Authors:  Aurélien Legrand; Patrick Jeanjean; Fanny Delanghe; Johann Peltier; Benoit Lecat; Hervé Dupont
Journal:  Crit Care       Date:  2013-03-27       Impact factor: 9.097

9.  Using MRI of the optic nerve sheath to detect elevated intracranial pressure.

Authors:  Heidi Harbison Kimberly; Vicki E Noble
Journal:  Crit Care       Date:  2008-09-24       Impact factor: 9.097

10.  Optic nerve sheath diameter measurement using bedside ultrasound: Is it accurate?

Authors:  Deepak Govil; Shrikanth Srinivasan
Journal:  Indian J Crit Care Med       Date:  2015-08
View more