Literature DB >> 17459481

Diagnostic accuracy of scanning laser polarimetry with enhanced versus variable corneal compensation.

T A Mai1, N J Reus, H G Lemij.   

Abstract

PURPOSE: To compare the diagnostic accuracy of scanning laser polarimetry (SLP) parameters between images taken with enhanced corneal compensation (ECC) and those with variable corneal compensation (VCC) and to explore the effect of atypical birefringence patterns on this accuracy.
DESIGN: Cross-sectional observational study. PARTICIPANTS: Forty-one healthy subjects and 92 patients with primary open-angle glaucoma.
METHODS: Variable corneal compensation and ECC images were obtained of 1 eye per subject, selected randomly if both eyes were eligible. For both ECC and VCC, the areas under the receiver operating characteristic curves (AUROCs) and the sensitivity at a specificity of > or =95% were calculated per parameter in all eyes. The analyses were reperformed separately in eyes with and without atypical birefringence patterns (ABP) images. MAIN OUTCOME MEASURES: The AUROCs and sensitivities at a specificity of > or =95% for various SLP parameters in all eyes and in eyes without ABP images.
RESULTS: The diagnostic accuracy for most standard parameters (temporal-superior-nasal-inferior-temporal [TSNIT] average, superior average, inferior average, and TSNIT standard deviation) in all eyes was statistically significantly higher with ECC than with VCC, except for the nerve fiber indicator (NFI). When only eyes without ABP were used for the analysis, the diagnostic accuracy of SLP parameters with VCC improved, and the differences in diagnostic accuracy between ECC and VCC for these parameters lost their statistical significance.
CONCLUSIONS: Standard SLP parameters (except for the NFI) generally had a higher diagnostic accuracy when eyes were imaged with ECC than with VCC because there were fewer ABP images with ECC than with VCC. Enhanced corneal compensation therefore may be more reliable than VCC for the detection of glaucoma. A future automated classifier, similar to the current NFI, may perform better if it is trained on data obtained with ECC. Clinically, retinal nerve fiber layer images with marked ABP, acquired with either ECC or VCC, should be viewed with caution.

Entities:  

Mesh:

Year:  2007        PMID: 17459481     DOI: 10.1016/j.ophtha.2007.01.022

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  14 in total

1.  Retinal nerve fiber layer evaluation of spectral domain optical coherence tomograph and scanning laser polarimeter to diagnose glaucoma.

Authors:  H L Rao; R K Yadav; U K Addepalli; S Chaudhary; S Senthil; N S Choudhari; C S Garudadri
Journal:  Eye (Lond)       Date:  2014-03-07       Impact factor: 3.775

2.  The impact of retardance pattern variability on nerve fiber layer measurements over time using GDx with variable and enhanced corneal compensation.

Authors:  Dilraj S Grewal; Mitra Sehi; Richard J Cook; David S Greenfield
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-06-23       Impact factor: 4.799

3.  Structural and Functional Evaluations for the Early Detection of Glaucoma.

Authors:  Katie A Lucy; Gadi Wollstein
Journal:  Expert Rev Ophthalmol       Date:  2016-09-14

Review 4.  Clinical application of ocular imaging.

Authors:  Zach Nadler; Gadi Wollstein; Hiroshi Ishikawa; Joel S Schuman
Journal:  Optom Vis Sci       Date:  2012-05       Impact factor: 1.973

Review 5.  Optic nerve head and fibre layer imaging for diagnosing glaucoma.

Authors:  Manuele Michelessi; Ersilia Lucenteforte; Francesco Oddone; Miriam Brazzelli; Mariacristina Parravano; Sara Franchi; Sueko M Ng; Gianni Virgili
Journal:  Cochrane Database Syst Rev       Date:  2015-11-30

6.  The Relationship between intraocular pressure and progressive retinal nerve fiber layer loss in glaucoma.

Authors:  Felipe A Medeiros; Luciana M Alencar; Linda M Zangwill; Pamela A Sample; Robert N Weinreb
Journal:  Ophthalmology       Date:  2009-04-19       Impact factor: 12.079

7.  Impact of atypical retardation patterns on detection of glaucoma progression using the GDx with variable corneal compensation.

Authors:  Felipe A Medeiros; Luciana M Alencar; Linda M Zangwill; Pamela A Sample; Remo Susanna; Robert N Weinreb
Journal:  Am J Ophthalmol       Date:  2009-04-17       Impact factor: 5.258

8.  The glaucoma detection capability of spectral-domain OCT and GDx-VCC deviation maps in early glaucoma patients with localized visual field defects.

Authors:  Jung Hwa Na; Kyoung Sub Lee; Jong Rak Lee; Youngrok Lee; Michael S Kook
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-07-03       Impact factor: 3.117

9.  Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes.

Authors:  Mirian Ara; Antonio Ferreras; Ana B Pajarin; Pilar Calvo; Michele Figus; Paolo Frezzotti
Journal:  Biomed Res Int       Date:  2015-06-22       Impact factor: 3.411

10.  The Northern Finland Birth Cohort Eye Study: Design and baseline characteristics.

Authors:  Ville Saarela; Elina Karvonen; Katri Stoor; Pasi Hägg; Marja Luodonpää; Jaana Kuoppala; Anja Taanila; Anja Tuulonen
Journal:  BMC Ophthalmol       Date:  2013-10-08       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.