Literature DB >> 17458539

End-inspiratory occlusion maneuver during transesophageal echocardiography for patent foramen ovale detection in intensive care unit patients.

Apostolos Koroneos1, Panagiotis Politis, Sotiris Malachias, Antonis S Manolis, Theodoros Vassilakopoulos.   

Abstract

OBJECTIVE: Mechanically ventilated patients in the intensive care unit cannot cooperate to perform the Valsalva maneuver during echocardiography for detection of patent foramen ovale. We evaluated the effectiveness of the end-inspiratory occlusion maneuver to enhance detection of patent foramen ovale in this patient population.
DESIGN: Prospective interventional study.
SETTING: The 40-bed intensive care unit of a university hospital. PATIENTS AND PARTICIPANTS: Twenty five sedated and mechanically ventilated intensive care unit patients referred by their attending physician for bedside transesophageal echocardiography and agitated saline contrast study for detection of patent foramen ovale. INTERVENTION: Agitated saline contrast study with end-inspiratory occlusion maneuver. MEASUREMENTS AND
RESULTS: All patients underwent a complete transesophageal echocardiographic study without any complications. Reduction in right atrial cross-sectional area (from 15.80 +/- 6.08 cm2 to 12.40 +/- 4.63 cm2; p < 0.001) and interatrial septum deviation during the maneuver were recorded in all patients. Microbubbles imaged in the left atrium within three cardiac cycles after injection of agitated saline diagnosed patent foramen ovale in three patients. When end-inspiratory occlusion maneuver was added, patent foramen ovale was diagnosed in seven patients (McNemar chi2 = 9.33, p = 0.0023).
CONCLUSIONS: The end-inspiratory occlusion maneuver enhances the sensitivity of transesophageal echocardiography with agitated saline contrast study for diagnosing intermittent patent foramen ovale in critically ill mechanically ventilated patients.

Entities:  

Mesh:

Year:  2007        PMID: 17458539     DOI: 10.1007/s00134-007-0639-6

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  19 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Echocardiographic contrast studies: initial experience.

Authors:  J B Seward; A J Tajik; J G Spangler; D G Ritter
Journal:  Mayo Clin Proc       Date:  1975-04       Impact factor: 7.616

3.  Contemporary management of patent foramen ovale.

Authors:  Bernhard Meier; James E Lock
Journal:  Circulation       Date:  2003-01-07       Impact factor: 29.690

4.  Paradoxical embolism.

Authors:  B I JOHNSON
Journal:  J Clin Pathol       Date:  1951-08       Impact factor: 3.411

5.  Percutaneous closure of patent foramen ovale in a patient presenting arterial hypoxaemia and supported with bi-ventricular assist device.

Authors:  Robert F Bonvini; Vitali Verin; René Lerch; Isabelle Gerard; Jorge Sierra; James C Spratt
Journal:  Intensive Care Med       Date:  2005-01-14       Impact factor: 17.440

6.  The detection of interatrial flow patency in awake and anesthetized patients: a comparative study using transnasal transesophageal echocardiography.

Authors:  C A Greim; H Trautner; K Krämer; P Zimmermann; C C Apfel; N Roewer
Journal:  Anesth Analg       Date:  2001-05       Impact factor: 5.108

Review 7.  The hemodynamic consequences of mechanical ventilation: an evolving story.

Authors:  M R Pinsky
Journal:  Intensive Care Med       Date:  1997-05       Impact factor: 17.440

8.  Patent foramen ovale is an important predictor of adverse outcome in patients with major pulmonary embolism.

Authors:  S Konstantinides; A Geibel; W Kasper; M Olschewski; L Blümel; H Just
Journal:  Circulation       Date:  1998-05-19       Impact factor: 29.690

9.  Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation. The effect of intrinsic positive end-expiratory pressure.

Authors:  A Rossi; S B Gottfried; L Zocchi; B D Higgs; S Lennox; P M Calverley; P Begin; A Grassino; J Milic-Emili
Journal:  Am Rev Respir Dis       Date:  1985-05

Review 10.  A critical review of patent foramen ovale detection using saline contrast echocardiography: when bubbles lie.

Authors:  Timothy D Woods; Ashvin Patel
Journal:  J Am Soc Echocardiogr       Date:  2006-02       Impact factor: 5.251

View more
  3 in total

Review 1.  Year in review in Intensive Care Medicine, 2007. II. Haemodynamics, pneumonia, infections and sepsis, invasive and non-invasive mechanical ventilation, acute respiratory distress syndrome.

Authors:  Massimo Antonelli; Elie Azoulay; Marc Bonten; Jean Chastre; Giuseppe Citerio; Giorgio Conti; Daniel De Backer; François Lemaire; Herwig Gerlach; Johan Groeneveld; Goran Hedenstierna; Duncan Macrae; Jordi Mancebo; Salvatore M Maggiore; Alexandre Mebazaa; Philipp Metnitz; Jerme Pugin; Jan Wernerman; Haibo Zhang
Journal:  Intensive Care Med       Date:  2008-01-31       Impact factor: 17.440

2.  Hemodynamic and respiratory factors that influence the opening of patent foramen ovale in mechanically ventilated patients.

Authors:  A Vavlitou; G Minas; S Zannetos; T Kyprianou; M Tsagourias; D Matamis
Journal:  Hippokratia       Date:  2016 Jul-Sep       Impact factor: 0.471

Review 3.  [Standardized contrast-enhanced ultrasound (CEUS) in clinical acute and emergency medicine and critical care (CEUS Acute) : Consensus statement of DGIIN, DIVI, DGINA, DGAI, DGK, ÖGUM, SGUM and DEGUM].

Authors:  Guido Michels; Rudolf Horn; Andreas Helfen; Andreas Hagendorff; Christian Jung; Beatrice Hoffmann; Natalie Jaspers; Horst Kinkel; Clemens-Alexander Greim; Fabian Knebel; Johann Bauersachs; Hans-Jörg Busch; Daniel Kiefl; Alexander O Spiel; Gernot Marx; Christoph F Dietrich
Journal:  Med Klin Intensivmed Notfmed       Date:  2022-02       Impact factor: 0.840

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.