Literature DB >> 17457878

RF refocused echoes of J-coupled spin systems: effects on RARE-based spectroscopic imaging.

Dirk Mayer1, Wolfgang Dreher, Dieter Leibfritz, Daniel M Spielman.   

Abstract

A numerical simulation tool was developed to calculate the echo amplitudes of J-coupled resonances within a series of radiofrequency (RF) refocused echoes. The signal modulation due to J-coupling in rapid acquisition with relaxation enhancement (RARE) is suppressed only when the inverse of the pulse interval (tau) is large compared to both the chemical shift (CS) difference (Deltadelta) of the coupled spins and the coupling constant. In contrast, the echo amplitudes in ultrafast low-flip-angle RARE (U-FLARE) oscillate around a quasi-steady-state value that is greater than zero (neglecting relaxation and diffusion) even when Deltadelta > 1/tau. The flip-angle distribution over the measured slice caused by the use of Gaussian-shape slice-selective refocusing pulses further reduces the echo oscillations. When the pulse interval falls short of the fast pulse rate regime, spectroscopic U-FLARE provides an improved spatial impulse response in the phase-encoding (PE) direction compared to spectroscopic RARE. (c) 2007 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2007        PMID: 17457878     DOI: 10.1002/mrm.21206

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Analysis of mcDESPOT- and CPMG-derived parameter estimates for two-component nonexchanging systems.

Authors:  Mustapha Bouhrara; David A Reiter; Hasan Celik; Kenneth W Fishbein; Richard Kijowski; Richard G Spencer
Journal:  Magn Reson Med       Date:  2015-07-03       Impact factor: 4.668

2.  Apparent diffusion coefficients of the five major metabolites measured in the human brain in vivo at 3T.

Authors:  Dinesh K Deelchand; Edward J Auerbach; Małgorzata Marjańska
Journal:  Magn Reson Med       Date:  2017-10-17       Impact factor: 4.668

3.  Rapid simultaneous high-resolution mapping of myelin water fraction and relaxation times in human brain using BMC-mcDESPOT.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Neuroimage       Date:  2016-10-08       Impact factor: 6.556

4.  Effect of Carr-Purcell refocusing pulse trains on transverse relaxation times of metabolites in rat brain at 9.4 Tesla.

Authors:  Dinesh Kumar Deelchand; Pierre-Gilles Henry; Małgorzata Marjańska
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.