Literature DB >> 17457861

In vivo imaging of changes in tumor oxygenation during growth and after treatment.

Anna Bratasz1, Ramasamy P Pandian, Yuanmu Deng, Sergey Petryakov, John C Grecula, Nilendu Gupta, Periannan Kuppusamy.   

Abstract

A novel procedure for in vivo imaging of the oxygen partial pressure (pO2) in implanted tumors is reported. The procedure uses electron paramagnetic resonance imaging (EPRI) of oxygen-sensing nanoprobes embedded in the tumor cells. Unlike existing methods of pO2 quantification, wherein the probes are physically inserted at the time of measurement, the new approach uses cells that are preinternalized (labeled) with the oxygen-sensing probes, which become permanently embedded in the developed tumor. Radiation-induced fibrosarcoma (RIF-1) cells, internalized with nanoprobes of lithium octa-n-butoxy-naphthalocyanine (LiNc-BuO), were allowed to grow as a solid tumor. In vivo imaging of the growing tumor showed a heterogeneous distribution of the spin probe, as well as oxygenation in the tumor volume. The pO2 images obtained after the tumors were exposed to a single dose of 30-Gy X-radiation showed marked redistribution as well as an overall increase in tissue oxygenation, with a maximum increase 6 hr after irradiation. However, larger tumors with a poorly perfused core showed no significant changes in oxygenation. In summary, the use of in vivo EPR technology with embedded oxygen-sensitive nanoprobes enabled noninvasive visualization of dynamic changes in the intracellular pO2 of growing and irradiated tumors. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17457861      PMCID: PMC2206209          DOI: 10.1002/mrm.21212

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  48 in total

1.  Monitoring oxygenation during the growth of a transplanted tumor.

Authors:  Anna Bratasz; Ramasamy P Pandian; Govindasamy Ilangovan; Periannan Kuppusamy
Journal:  Adv Exp Med Biol       Date:  2006       Impact factor: 2.622

2.  The relationship between partial pressure of oxygen and perfusion in two murine tumors after X-ray irradiation: a combined gadopentetate dimeglumine dynamic magnetic resonance imaging and in vivo electron paramagnetic resonance oximetry study.

Authors:  F Goda; G Bacic; J A O'Hara; B Gallez; H M Swartz; J F Dunn
Journal:  Cancer Res       Date:  1996-07-15       Impact factor: 12.701

3.  Changes of oxygen tension in experimental tumors after a single dose of X-ray irradiation.

Authors:  F Goda; J A O'Hara; E S Rhodes; K J Liu; J F Dunn; G Bacic; H M Swartz
Journal:  Cancer Res       Date:  1995-06-01       Impact factor: 12.701

4.  Tumor oxygenation predicts for the likelihood of distant metastases in human soft tissue sarcoma.

Authors:  D M Brizel; S P Scully; J M Harrelson; L J Layfield; J M Bean; L R Prosnitz; M W Dewhirst
Journal:  Cancer Res       Date:  1996-03-01       Impact factor: 12.701

5.  Oxygenation and metabolic status of KHT tumors as measured simultaneously by 19F magnetic resonance imaging and 31P magnetic resonance spectroscopy.

Authors:  N J Baldwin; T C Ng
Journal:  Magn Reson Imaging       Date:  1996       Impact factor: 2.546

6.  Noninvasive imaging of the distribution in oxygen in tissue in vivo using near-infrared phosphors.

Authors:  S A Vinogradov; L W Lo; W T Jenkins; S M Evans; C Koch; D F Wilson
Journal:  Biophys J       Date:  1996-04       Impact factor: 4.033

7.  Non-invasive physiology: 19F NMR of perfluorocarbons.

Authors:  R P Mason
Journal:  Artif Cells Blood Substit Immobil Biotechnol       Date:  1994

8.  Comparing techniques of measuring tumor hypoxia in different murine tumors: Eppendorf pO2 Histograph, [3H]misonidazole binding and paired survival assay.

Authors:  M C Kavanagh; A Sun; Q Hu; R P Hill
Journal:  Radiat Res       Date:  1996-04       Impact factor: 2.841

9.  Hypoxic fractions measured in murine tumors and normal tissues using the comet assay.

Authors:  P L Olive; C M Vikse; R E Durand
Journal:  Int J Radiat Oncol Biol Phys       Date:  1994-06-15       Impact factor: 7.038

10.  The response to carbogen breathing in experimental tumour models monitored by gradient-recalled echo magnetic resonance imaging.

Authors:  S P Robinson; L M Rodrigues; A S Ojugo; P M McSheehy; F A Howe; J R Griffiths
Journal:  Br J Cancer       Date:  1997       Impact factor: 7.640

View more
  29 in total

1.  Impact of stromal sensitivity on radiation response of tumors implanted in SCID hosts revisited.

Authors:  Mónica García-Barros; Tin Htwe Thin; Jerzy Maj; Carlos Cordon-Cardo; Adriana Haimovitz-Friedman; Zvi Fuks; Richard Kolesnick
Journal:  Cancer Res       Date:  2010-10-05       Impact factor: 12.701

2.  Multiple-stepped Zeeman field offset method applied in acquiring enhanced resolution spin-echo electron paramagnetic resonance images.

Authors:  Payam Seifi; Boris Epel; Colin Mailer; Howard J Halpern
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  In vivo observation of intracellular oximetry in perfluorocarbon-labeled glioma cells and chemotherapeutic response in the CNS using fluorine-19 MRI.

Authors:  Deepak K K Kadayakkara; Jelena M Janjic; Lisa K Pusateri; Won-Bin Young; Eric T Ahrens
Journal:  Magn Reson Med       Date:  2010-09-21       Impact factor: 4.668

4.  Transient decrease in tumor oxygenation after intravenous administration of pyruvate.

Authors:  Keita Saito; Shingo Matsumoto; Nallathamby Devasahayam; Sankaran Subramanian; Jeeva P Munasinghe; H Douglas Morris; Martin J Lizak; Jan Henrik Ardenkjaer-Larsen; James B Mitchell; Murali C Krishna
Journal:  Magn Reson Med       Date:  2011-10-17       Impact factor: 4.668

5.  Electrochemical mapping of oxygenation in the three-dimensional multicellular tumour hemi-spheroid.

Authors:  Disha B Sheth; Miklόs Gratzl
Journal:  Proc Math Phys Eng Sci       Date:  2019-05-22       Impact factor: 2.704

Review 6.  Imaging tumor hypoxia to advance radiation oncology.

Authors:  Chen-Ting Lee; Mary-Keara Boss; Mark W Dewhirst
Journal:  Antioxid Redox Signal       Date:  2014-03-24       Impact factor: 8.401

7.  Mapping Tumor Hypoxia In Vivo Using Pattern Recognition of Dynamic Contrast-enhanced MRI Data.

Authors:  Radka Stoyanova; Kris Huang; Kiri Sandler; Hyungjoon Cho; Sean Carlin; Pat B Zanzonico; Jason A Koutcher; Ellen Ackerstaff
Journal:  Transl Oncol       Date:  2012-12-01       Impact factor: 4.243

8.  A paramagnetic implant containing lithium naphthalocyanine microcrystals for high-resolution biological oximetry.

Authors:  Guruguhan Meenakshisundaram; Ramasamy P Pandian; Edward Eteshola; Stephen C Lee; Periannan Kuppusamy
Journal:  J Magn Reson       Date:  2009-11-26       Impact factor: 2.229

9.  Concurrent Longitudinal EPR Monitoring of Tissue Oxygenation, Acidosis, and Reducing Capacity in Mouse Xenograft Tumor Models.

Authors:  Andrey A Bobko; Jason Evans; Nicholas C Denko; Valery V Khramtsov
Journal:  Cell Biochem Biophys       Date:  2016-05-18       Impact factor: 2.194

10.  Myocardial oxygenation and functional recovery in infarct rat hearts transplanted with mesenchymal stem cells.

Authors:  Simi M Chacko; Mahmood Khan; M Lakshmi Kuppusamy; Ramasamy P Pandian; Saradhadevi Varadharaj; Karuppaiyah Selvendiran; Anna Bratasz; Brian K Rivera; Periannan Kuppusamy
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-03-13       Impact factor: 4.733

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.