Literature DB >> 17457818

Distributing a fixed amount of cyclic loading to tendon explants over longer periods induces greater cellular and mechanical responses.

Aaditya C Devkota1, Mari Tsuzaki, Louis C Almekinders, Albert J Banes, Paul S Weinhold.   

Abstract

Tendon overuse injuries are a major source of clinical concern. Cyclic loading causes material damage and induces biochemical responses in tendon. The purpose of this study was to examine the biochemical and biomechanical tendon response after applying cyclical loading over varying durations. Avian flexor digitorum profundus tendons were loaded (3 or 12 MPa) to a fixed number of cycles across either 1 or 12 days in vitro. The tendon response evaluations included biomechanical data gathered during loading and subsequent failure testing. Evaluations also included cellular viability, cell death, and proteoglycan, collagen, collagenase, and prostaglandin E(2) (PGE(2)) content measurements obtained from tissue specimens and media samples. Significant strains (up to 2%) accumulated during loading. Loading to 12 MPa significantly reduced maximum stress (33% and 27%) and energy density (42% and 50%) when applied across 1 or 12 days, respectively. Loading to 3 MPa also caused a 40% reduction in energy density, but only when applied across 12 days. Cell death and collagenase activity increased significantly with increasing magnitude and duration. However, no differences occurred in cell viability or collagen content. Glycosaminoglycan content increased 50% with load magnitude, while PGE(2) production increased 2.5-fold with loading magnitude and 11-fold with increased duration. Mechanical fatigue-induced mechanical property changes were exhibited by the tendons in response to increased loading magnitude across just 1 day. However, when the same loading was applied over a longer period, most outcomes were magnified substantially, relative to the short duration regimens. This is presumably due to the increased response time for the complex cellular response to loading. A key contributor may be the inflammatory mediator, PGE(2), which exhibited large magnitude and duration dependent increases to cyclic loading.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17457818     DOI: 10.1002/jor.20389

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  12 in total

1.  An integrated instrument for rapidly deforming living cells using rapid pressure pulses and simultaneously monitoring applied strain in near real time.

Authors:  M E Green; P B Goforth; L S Satin; B J Love
Journal:  Rev Sci Instrum       Date:  2010-12       Impact factor: 1.523

Review 2.  The (dys)functional extracellular matrix.

Authors:  Benjamin R Freedman; Nathan D Bade; Corinne N Riggin; Sijia Zhang; Philip G Haines; Katy L Ong; Paul A Janmey
Journal:  Biochim Biophys Acta       Date:  2015-04-27

Review 3.  A brief history of tendon and ligament bioreactors: Impact and future prospects.

Authors:  Nathaniel A Dyment; Jennifer G Barrett; Hani A Awad; Catherine A Bautista; Albert J Banes; David L Butler
Journal:  J Orthop Res       Date:  2020-07-01       Impact factor: 3.494

Review 4.  Fatigue loading of tendon.

Authors:  Jennifer H Shepherd; Hazel R C Screen
Journal:  Int J Exp Pathol       Date:  2013-08       Impact factor: 1.925

5.  Coordinate regulation of IL-1beta and MMP-13 in rat tendons following subrupture fatigue damage.

Authors:  Hui B Sun; Yonghui Li; David T Fung; Robert J Majeska; Mitchell B Schaffler; Evan L Flatow
Journal:  Clin Orthop Relat Res       Date:  2008-05-10       Impact factor: 4.176

Review 6.  Fatigue damage of collagenous tissues: experiment, modeling and simulation studies.

Authors:  Caitlin Martin; Wei Sun
Journal:  J Long Term Eff Med Implants       Date:  2015

7.  Periodontal biomechanics: finite element simulations of closing stroke and power stroke in equine cheek teeth.

Authors:  Vanessa Cordes; Matthias Lüpke; Moritz Gardemin; Hermann Seifert; Carsten Staszyk
Journal:  BMC Vet Res       Date:  2012-07-11       Impact factor: 2.741

8.  Insulin-like growth factor-1 and bone morphogenetic protein-2 jointly mediate prostaglandin E2-induced adipogenic differentiation of rat tendon stem cells.

Authors:  Junpeng Liu; Lei Chen; You zhou; Xiangzhou Liu; Kanglai Tang
Journal:  PLoS One       Date:  2014-01-09       Impact factor: 3.240

9.  Dynamic Loading and Tendon Healing Affect Multiscale Tendon Properties and ECM Stress Transmission.

Authors:  Benjamin R Freedman; Ashley B Rodriguez; Ryan J Leiphart; Joseph B Newton; Ehsan Ban; Joseph J Sarver; Robert L Mauck; Vivek B Shenoy; Louis J Soslowsky
Journal:  Sci Rep       Date:  2018-07-18       Impact factor: 4.379

10.  Early stage fatigue damage occurs in bovine tendon fascicles in the absence of changes in mechanics at either the gross or micro-structural level.

Authors:  Jennifer H Shepherd; Graham P Riley; Hazel R C Screen
Journal:  J Mech Behav Biomed Mater       Date:  2014-07-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.