Literature DB >> 17456867

Contrast-enhanced cardiac MR imaging in the detection of reduced coronary flow velocity reserve.

Achim A Barmeyer1, Alexander Stork, Kai Muellerleile, Claudia Tiburtius, Anne K Schofer, Thomas A Heitzer, Thomas Hofmann, Gerhard Adam, Thomas Meinertz, Gunnar K Lund.   

Abstract

PURPOSE: To prospectively evaluate the accuracy of contrast material-enhanced cardiac magnetic resonance (MR) imaging for determining impaired coronary flow velocity reserve (CFR) by using Doppler flow measurement as the reference standard.
MATERIALS AND METHODS: The study was approved by the institutional ethics committee, and all patients gave written informed consent. Eligible patients underwent contrast-enhanced cardiac MR imaging and invasive measurement of CFR. For contrast-enhanced MR imaging, a three-section single-shot saturation recovery gradient-recalled echo sequence with steady-state free precession was used. Sections were divided into six segments. For each segment, a transmural and subendocardial myocardial perfusion reserve index (MPRI) was calculated by using the upslope of the signal intensity-time curve during the first pass of contrast material at rest and during adenosine infusion (140 microg per kilogram body weight per minute). MPRIs of vascular regions were compared with the corresponding CFR. Receiver operating characteristic (ROC) analysis was performed to find the number of segments needed for best diagnostic accuracy of MPRI and to find a cutoff value for MPRI in the detection of a reduced CFR.
RESULTS: Thirty-five patients were evaluated (male-to-female ratio, 27:8; mean age +/- standard deviation, 63.5 years +/- 8.2; mean body mass index, 28.8 kg/m(2) +/- 3.8), and 43 vascular regions were analyzed. A linear correlation was found between the MPRI and CFR (r = 0.44, P < .05). The MPRI was significantly lower in vascular regions with a CFR of less than 2.00 than in regions with a CFR of 2.00 or greater (P < .05). Detection of a CFR of less than 2.00 was more accurate with subendocardial MPRI measurements than with transmural measurements. The mean subendocardial MPRI of the segments with the three lowest MPRIs of a vascular region showed the best diagnostic performance in the detection of a CFR of less than 2.00 (area under the ROC curve, 0.85; sensitivity, 84%; specificity, 75%) by using a cutoff value of 1.21.
CONCLUSION: The diagnostic accuracy of subendocardial perfusion analysis in contrast-enhanced cardiac MR imaging is higher than that of transmural analysis.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17456867     DOI: 10.1148/radiol.2432060331

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  High resolution myocardial magnetic resonance stress perfusion imaging at 3 T using a 1 M contrast agent.

Authors:  Bernhard D Klumpp; Achim Seeger; Christina Doesch; Joerg Doering; Tobias Hoevelborn; Ulrich Kramer; Michael Fenchel; Meinrad P Gawaz; Claus D Claussen; Stephan Miller
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

2.  Quantitative assessment of magnetic resonance derived myocardial perfusion measurements using advanced techniques: microsphere validation in an explanted pig heart system.

Authors:  Andreas Schuster; Niloufar Zarinabad; Masaki Ishida; Matthew Sinclair; Jeroen Phm van den Wijngaard; Geraint Morton; Gilion Ltf Hautvast; Boris Bigalke; Pepijn van Horssen; Nicolas Smith; Jos Ae Spaan; Maria Siebes; Amedeo Chiribiri; Eike Nagel
Journal:  J Cardiovasc Magn Reson       Date:  2014-10-14       Impact factor: 5.364

3.  Defining the flow-limiting stenosis noninvasively for management of patients with coronary artery disease.

Authors:  Tiago A Magalhães; João A C Lima
Journal:  JACC Cardiovasc Interv       Date:  2013-12-11       Impact factor: 11.195

4.  Diagnostic accuracy of adenosine stress cardiovascular magnetic resonance following acute ST-segment elevation myocardial infarction post primary angioplasty.

Authors:  Dennis T L Wong; Michael C H Leung; Rajiv Das; Gary Y H Liew; Kerry Williams; Benjamin K Dundon; Payman Molaee; Karen S L Teo; Ian T Meredith; Matthew I Worthley; Stephen G Worthley
Journal:  J Cardiovasc Magn Reson       Date:  2011-10-22       Impact factor: 5.364

5.  Diagnostic value of transmural perfusion ratio derived from dynamic CT-based myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis.

Authors:  Adriaan Coenen; Marisa M Lubbers; Akira Kurata; Atsushi Kono; Admir Dedic; Raluca G Chelu; Marcel L Dijkshoorn; Alexia Rossi; Robert-Jan M van Geuns; Koen Nieman
Journal:  Eur Radiol       Date:  2016-10-04       Impact factor: 5.315

6.  Cardiovascular magnetic resonance imaging in the prospective, population-based, Hamburg City Health cohort study: objectives and design.

Authors:  Sebastian Bohnen; Maxim Avanesov; Annika Jagodzinski; Renate B Schnabel; Tanja Zeller; Mahir Karakas; Jan Schneider; Enver Tahir; Ersin Cavus; Clemens Spink; Ulf K Radunski; Francisco Ojeda; Gerhard Adam; Stefan Blankenberg; Gunnar K Lund; Kai Muellerleile
Journal:  J Cardiovasc Magn Reson       Date:  2018-09-24       Impact factor: 5.364

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.