Literature DB >> 17456490

Intra-abdominal pressure measurement: validation of intragastric pressure as a measure of intra-abdominal pressure.

D Turnbull1, S Webber, C H Hamnegard, G H Mills.   

Abstract

BACKGROUND: The diagnosis of abdominal compartment syndrome depends upon the demonstration of an elevated intra-abdominal pressure (IAP). Direct measures of IAP are impractical in the critical care unit; intravesical pressure (IVP) and intragastric pressure (IGP) should represent acceptable surrogate measures. IVP is the preferred measure of IAP in critical care. We considered that IGP represents a practical alternative. The objective of this preliminary study was to observe the relationship between IGP and IAP.
METHODS: After Institutional Ethics Board approval, 29 patients having elective laparoscopic surgery were recruited. IAP was measured directly via the abdominal trochar. This was compared with IGP measured via a commercial balloon catheter placed into the stomach.
RESULTS: Measured IGP was always more positive than IAP; both showed linear correlation (r2>0.9). When IGP was calibrated against IAP, an estimated difference between the IGP and IAP of+/-2.5 mm Hg for 95% of the measurements was seen.
CONCLUSIONS: The study demonstrates the strength of the relationship between IGP and IAP in normal individuals. Application of IGP measurement in the critical care patient is necessary to demonstrate its suitability for continuous IAP assessment.

Entities:  

Mesh:

Year:  2007        PMID: 17456490     DOI: 10.1093/bja/aem060

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  7 in total

1.  Why we need guidelines and recommendations for research on intra-abdominal hypertension.

Authors:  Manu L N G Malbrain; Inneke De Laet
Journal:  Intensive Care Med       Date:  2009-10-20       Impact factor: 17.440

2.  [Importance of abdominal compartment syndrome in Germany: a questionnaire].

Authors:  J Otto; D Kaemmer; J Höer; M Jansen; V Schumpelick; M Strik; R Kuhlen; A Schachtrupp
Journal:  Anaesthesist       Date:  2009-06       Impact factor: 1.041

3.  Direct intra-abdominal pressure monitoring via piezoresistive pressure measurement: a technical note.

Authors:  Jens Otto; Daniel Kaemmer; Marcel Binnebösel; Marc Jansen; Rolf Dembinski; Volker Schumpelick; Alexander Schachtrupp
Journal:  BMC Surg       Date:  2009-04-21       Impact factor: 2.102

4.  Bench Validation of a Handcrafted Prototype Catheter for Intra-gastric Pressure Monitoring.

Authors:  Alberto Federico García; Julián Chica Yantén; Álvaro Ignacio Sánchez; Jose Luis Aldana; Jorge Humberto Mejía; Daniela Burbano; Camilo Salazar
Journal:  World J Surg       Date:  2020-06       Impact factor: 3.352

5.  A Novel Method (CiMON) for Continuous Intra-Abdominal Pressure Monitoring: Pilot Test in a Pig Model.

Authors:  Joost Wauters; Liesbeth Spincemaille; Anne-Sophie Dieudonne; Kenny Van Zwam; Alexander Wilmer; Manu L N G Malbrain
Journal:  Crit Care Res Pract       Date:  2012-02-20

6.  Comparing intra-abdominal pressures in different body positions via a urinary catheter and nasogastric tube: a pilot study.

Authors:  Nirooshan Rooban; Adrian Regli; Wendy A Davis; Bart L De Keulenaer
Journal:  Ann Intensive Care       Date:  2012-07-05       Impact factor: 6.925

7.  Intrabladder pressure as predictor of intra-abdominal pressure in horses.

Authors:  Vanessa B de Paula; Paulo A Canola; Gabriela G Rivera; Dárcio Z Filho; Gabriel P D Amaral; Guilherme C Ferraz; Antônio S Ferraudo; Júlio C Canola
Journal:  PLoS One       Date:  2019-10-10       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.