Literature DB >> 17452178

A method of measuring anterior chamber volume using the anterior segment optical coherence tomographer and specialized software.

Ningli Wang1, Bingsong Wang, Gaoshou Zhai, Kun Lei, Lan Wang, Nathan Congdon.   

Abstract

PURPOSE: To describe and evaluate a new method for measuring anterior chamber volume (ACV).
DESIGN: Observational case series.
METHODS: The authors measured ACV using the anterior chamber (AC) optical coherence tomographer (OCT) and applied image-processing software developed by them. Repeatability was evaluated. The ACV was measured in patient groups with normal ACs, shallow ACs, and deep ACs. The volume difference before and after laser peripheral iridotomy (LPI) was analyzed for the shallow and deep groups.
RESULTS: Coefficients of repeatability for intraoperator, interoperator, and interimage measurements were 0.406%, 0.958%, and 0.851%, respectively. The limits of agreement for intraoperator and interoperator measurement were -0.911 microl to 1.343 microl and -7.875 microl to -2.463 microl, respectively. There were significant ACV differences in normal, shallow, and deep AC eyes (P < .001) and before and after LPI in shallow AC (P < .001) and deep AC (P = .008) eyes.
CONCLUSIONS: The ACV values obtained by this method were repeatable and in accord with clinical observation.

Entities:  

Mesh:

Year:  2006        PMID: 17452178     DOI: 10.1016/j.ajo.2006.11.051

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  3 in total

1.  Residual anterior chamber angle closure in narrow-angle eyes following laser peripheral iridotomy: anterior segment optical coherence tomography quantitative study.

Authors:  Kyoung Sub Lee; Kyung Rim Sung; Sung Yong Kang; Jung Woo Cho; Dong Yoon Kim; Michael S Kook
Journal:  Jpn J Ophthalmol       Date:  2011-05-11       Impact factor: 2.447

2.  Validation of optical coherence tomography-based crystalline lens thickness measurements in children.

Authors:  Bret M Lehman; David A Berntsen; Melissa D Bailey; Karla Zadnik
Journal:  Optom Vis Sci       Date:  2009-03       Impact factor: 1.973

3.  Anterior Segment Optical Coherence Tomography and its Clinical Applications in Glaucoma.

Authors:  Haitao Li; Vishal Jhanji; Syril Dorairaj; Andrea Liu; Dennis Sc Lam; Christopher K Leung
Journal:  J Curr Glaucoma Pract       Date:  2012-08-16