Literature DB >> 17451981

Targeted-ROI imaging in electron paramagnetic resonance imaging.

Xiaochuan Pan1, Dan Xia, Howard Halpern.   

Abstract

Electron paramagnetic resonance imaging (EPRI) is a technique that has been used for in vivo oxygen imaging of small animals. In continuous wave (CW) EPRI, the measurement can be interpreted as a sampled 4D Radon transform of the image function. The conventional filtered-backprojection (FBP) algorithm has been used widely for reconstructing images from full knowledge of the Radon transform acquired in CW EPRI. In practical applications of CW EPRI, one often is interested in information only in a region of interest (ROI) within the imaged subject. It is desirable to accurately reconstruct an ROI image only from partial knowledge of the Radon transform because acquisition of the partial data set can lead to considerable reduction of imaging time. The conventional FBP algorithm cannot, however, reconstruct accurate ROI images from partial knowledge of the Radon transform of even dimension. In this work, we describe two new algorithms, which are referred to as the backprojection filtration (BPF) and minimum-data filtered-backprojection (MDFBP) algorithms, for accurate ROI-image reconstruction from a partial Radon transform (or, truncated Radon transform) in CW EPRI. We have also performed numerical studies in the context of ROI-image reconstruction of a synthetic 2D image with density similar to that found in a small animal EPRI. This demonstrates both the inadequacy of the conventional FBP algorithm and the success of BPF and MDFBP algorithms in ROI reconstruction. The proposed ROI imaging approach promises a means to substantially reduce image acquisition time in CW EPRI.

Entities:  

Mesh:

Year:  2007        PMID: 17451981     DOI: 10.1016/j.jmr.2007.02.010

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  5 in total

1.  Compressed sensing of spatial electron paramagnetic resonance imaging.

Authors:  David H Johnson; Rizwan Ahmad; Guanglong He; Alexandre Samouilov; Jay L Zweier
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

2.  Comparison of 250 MHz electron spin echo and continuous wave oxygen EPR imaging methods for in vivo applications.

Authors:  Boris Epel; Subramanian V Sundramoorthy; Eugene D Barth; Colin Mailer; Howard J Halpern
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

Review 3.  Molecular imaging of tumor hypoxia with positron emission tomography.

Authors:  Olivia J Kelada; David J Carlson
Journal:  Radiat Res       Date:  2014-03-27       Impact factor: 2.841

4.  Positron Emission Tomography Imaging of Hypoxia.

Authors:  Suzanne E Lapi; Thomas F Voller; Michael J Welch
Journal:  PET Clin       Date:  2009-01-01

5.  Locations of radical species in black pepper seeds investigated by CW EPR and 9GHz EPR imaging.

Authors:  Kouichi Nakagawa; Boris Epel
Journal:  Spectrochim Acta A Mol Biomol Spectrosc       Date:  2014-04-30       Impact factor: 4.098

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.