Literature DB >> 17448973

The role of [18F]fluoride positron emission tomography in the early detection of aseptic loosening of total knee arthroplasty.

T Sterner1, R Pink, L Freudenberg, T Jentzen, H Quitmann, A Bockisch, F Löer.   

Abstract

Total knee arthroplasty is successful in the treatment of degenerative, arthritic or injured joints. But the most important long term complication seems to be aseptic loosening. An inflammatory process at the bone/cement or bone/prosthesis interface leads to a severe osteolysis. Although early diagnosis is very important the standard techniques often fail. [(18)F]Fluoride ion positron emission tomography (F-PET) is an appropriate tracer paired with a modern method for the evaluation of increased bone metabolism at the bone/prosthesis interface. In this preliminary study we describe for the first time the value of F-PET in the early diagnosis of aseptic loosening. We studied 14 painful knee arthoplasties. In 6 cases the definite diagnosis was determined by surgical procedure, for 8 cases a long clinical follow-up of the least 6 months after the onset of symptoms led to the diagnosis. The F-PET scans were obtained by with an ECAT EXACT HR+ scanner with and without attenuation correction in the two-and three-dimensional mode. An intermediate or high uptake along the bone/prosthesis or bone/cement interface including either the tibial stem or the half of the femoral component was suspected to be aseptic loose. The result were compared with plain radiographs. We found a sensitivity of 100%, a specificity of 56% and an accuracy of 71%. No false negative results were detected, in 4 patients one component as false positive. The sensitivity, specificity and accuracy for the plain radiograph of the same patients were 43%, 86% and 64%, respectively. In conclusion PET seems to be a promising new method in the early diagnosis of painful TKA because of its excellent spatial solution. In combination with the bone seeking tracer [(18) F]fluoride, PET allows the detection of aseptic loosening and the differentiation to the simple synovitis. Our preliminary results suggest that F-PET could be a useful tool although we examined a small group of patients.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17448973     DOI: 10.1016/j.ijsu.2006.05.002

Source DB:  PubMed          Journal:  Int J Surg        ISSN: 1743-9159            Impact factor:   6.071


  9 in total

1.  (18)F-NaF PET/CT: EANM procedure guidelines for bone imaging.

Authors:  M Beheshti; F M Mottaghy; F Paycha; F F F Behrendt; T Van den Wyngaert; I Fogelman; K Strobel; M Celli; S Fanti; F Giammarile; B Krause; W Langsteger
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-07-23       Impact factor: 9.236

Review 2.  Prosthetic joint infections: radionuclide state-of-the-art imaging.

Authors:  Filip Gemmel; Hans Van den Wyngaert; Charito Love; M M Welling; Paul Gemmel; Christopher J Palestro
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-02-24       Impact factor: 9.236

3.  Therapeutic impact of [(18)F]fluoride positron-emission tomography/computed tomography on patients with unclear foot pain.

Authors:  Dorothee Rita Fischer; Gerardo J Maquieira; Norman Espinosa; Marco Zanetti; Rolf Hesselmann; Anass Johayem; Thomas F Hany; Gustav K von Schulthess; Klaus Strobel
Journal:  Skeletal Radiol       Date:  2010-02-23       Impact factor: 2.199

4.  Sodium 18F-fluoride PET/CT of bone, joint, and other disorders.

Authors:  Hossein Jadvar; Bhushan Desai; Peter S Conti
Journal:  Semin Nucl Med       Date:  2015-01       Impact factor: 4.446

Review 5.  Nuclear medicine and the failed joint replacement: Past, present, and future.

Authors:  Christopher J Palestro
Journal:  World J Radiol       Date:  2014-07-28

6.  Diagnostic algorithm in aseptic TKA failure - What is evidence-based?

Authors:  E Röhner; M Heinecke; G Matziolis
Journal:  J Orthop       Date:  2021-03-21

Review 7.  Review of the role of dynamic 18F-NaF PET in diagnosing and distinguishing between septic and aseptic loosening in hip prosthesis.

Authors:  Olu Adesanya; Andrew Sprowson; James Masters; Charles Hutchinson
Journal:  J Orthop Surg Res       Date:  2015-01-16       Impact factor: 2.359

8.  Knee Implant Loosening Detection: A Vibration Analysis Investigation.

Authors:  Arash Arami; Jean-Romain Delaloye; Hossein Rouhani; Brigitte M Jolles; Kamiar Aminian
Journal:  Ann Biomed Eng       Date:  2017-10-24       Impact factor: 3.934

9.  Feasibility of Magnetic Resonance Imaging Monitoring of Postoperative Total Knee Arthroplasty without Metal Artifacts: A Preliminary Study of a Novel Implant Model.

Authors:  Xiangchao Meng; Zhe Du; You Wang
Journal:  Biomed Res Int       Date:  2018-10-23       Impact factor: 3.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.