Literature DB >> 17446541

Clinical comparison of two optional vena cava filters.

Isabella S Keller1, Christoph Meier, Roger Pfiffner, Emanuela Keller, Thomas Pfammatter.   

Abstract

PURPOSE: To compare the clinical safety and efficiency of two optional inferior vena cava (IVC) filters.
MATERIAL AND METHODS: Ninety-three consecutive Günther Tulip filters (92 patients) were compared with 83 consecutive OptEase filters (80 patients). Filters were placed at the same institution in patients with high-risk multiple trauma or those undergoing neurosurgery with contraindications to primary prophylaxis (70 patients in the Günther Tulip group and 44 in the OptEase group) and in patients with venous thromboembolism and contraindications to anticoagulation (22 patients in the Günther Tulip group and 36 in the OptEase group). The filters were placed in an angiography suite. Catheter vena cavography was performed before filter placement and intended retrieval. Permanent filters were followed-up with duplex ultrasonography and conventional radiography.
RESULTS: All filters were inserted infrarenally without any complications. Fluoroscopy times for placement and retrieval were longer for the Günther Tulip group than the OptEase group. The mean dwelling time was 11 days (range, 3-27 days) for the Günther Tulip filters and 13.8 days (range, 1-34 days) for the OptEase filters. No symptomatic pulmonary emboli (PE) occurred in patients with intended temporary filtration while the devices were in place. Forty-six of the 93 Günther Tulip filters (49%) and 58 of the 83 OptEase filters (70%) were removed. Two Günther Tulip filters could not be retrieved for technical reasons. The mean follow-up for the permanent Günther Tulip (n = 19) and OptEase (n = 8) filters was 41 and 7 months, respectively. One patient from each group had late caval thrombosis. There were no cases of filter migration or disintegration.
CONCLUSION: Both optional IVC filters are safe and seem to prevent symptomatic PE. On the basis of the fluoroscopy times, the OptEase filters appear to be more operator-friendly. Late filter-associated complications are rare with these filter designs.

Entities:  

Mesh:

Year:  2007        PMID: 17446541     DOI: 10.1016/j.jvir.2007.02.007

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  9 in total

Review 1.  Interventional radiology for paediatric trauma.

Authors:  Manrita K Sidhu; Mark J Hogan; Dennis W W Shaw; Thomas Burdick
Journal:  Pediatr Radiol       Date:  2008-12-17

Review 2.  Optional inferior vena caval filters: where are we now?

Authors:  A N Keeling; T B Kinney; M J Lee
Journal:  Eur Radiol       Date:  2008-04-02       Impact factor: 5.315

Review 3.  Back to the Basics: Inferior Vena Cava Filters.

Authors:  Brian Covello; Martin Radvany
Journal:  Semin Intervent Radiol       Date:  2022-08-31       Impact factor: 1.780

4.  [Vena cava filter. Which indications remain in the era of differentiated anticoagulation?].

Authors:  A H Mahnken
Journal:  Radiologe       Date:  2013-03       Impact factor: 0.635

Review 5.  Optional vena cava filters: indications, management, and results.

Authors:  Hanno Hoppe
Journal:  Dtsch Arztebl Int       Date:  2009-06-12       Impact factor: 5.594

6.  [Vena cava filters in trauma patients].

Authors:  D Baschera; J Sebunya; C Walter; R Zellweger
Journal:  Unfallchirurg       Date:  2010-09       Impact factor: 1.000

7.  Update on vena cava filters.

Authors:  Teresa L Carman; Alaa Alahmad
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-04

8.  Successful cases of difficult inferior vena cava filter retrieval with the use of biopsy forceps: Biopsy forceps technique.

Authors:  Masaya Nakashima; Hideaki Kobayashi; Yasushi Takenouchi; Takashi Nakayama; Masayoshi Kobayashi
Journal:  SAGE Open Med Case Rep       Date:  2014-12-12

9.  Bidirectional Pull-Back Technique for Retrieval of Strut-Embedded Cylinder-Shaped Filters in Inferior Vena Cava.

Authors:  Xiaolong Du; Chenglong Li; Aimin Qian; Yeqing Zhang; Wendong Li; Huiying Yu; Xiaoqiang Li; Lingshang Kong
Journal:  Med Sci Monit       Date:  2017-06-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.