Literature DB >> 17445336

Transcatheter closure of coronary arterial fistulas using the new Amplatzer vascular plug.

Gunther Fischer1, Sotiria C Apostolopoulou, Spyros Rammos, Maria Kiaffas, Hans Heiner Kramer.   

Abstract

We report our initial experience in using the Amplatzer vascular plug for closure of coronary arterial fistulas. The self-expanding, cylindrical, device is made from Nitinol wire mesh, and is available from 4 to 16 millimetres in diameter. We have now used the device to close fistulas in 3 patients, aged from 3 to 14 years, who presented with ratios of pulmonary-to-systemic flow from 1.5 to 3. In 2 patients, fistulas arising from the proximal right and left coronary arteries, with maximal diameters of 9 and 10 millimetres, respectively, had their narrowest diameter, of 6 millimetres, proximal to the entrance into the right atrium via a saccular aneurysm. The third fistula, with a maximal diameter of 16 millimetres, and with its origin from the circumflex coronary artery, entered the right atrium with nearly unrestricted flow, its narrowest diameter being 8 millimetres. For interventional closure, we chose plugs twice the diameter of the narrowest segment of the fistula, thus using 2 devices of 12 millimetres and one of 16 millimetres diameter. An arteriovenous loop was established through the fistula by snaring an exchange guide wire. Using a 7 or 8 French guide catheter inserted through the femoral vein, all plugs were placed at the narrowest segment of the fistula, leading to immediate complete closure of 2 fistulas. The third patient, with a fistula of the circumflex coronary artery, who received the largest plug initially had residual flow, but the fistula was found to be completely occluded at 12 months follow-up examination. We have demonstrated, therefore, safe and effective usage of the new vascular plug for transcatheter closure of moderate- to large-sized coronary arterial fistulas. The plug offers an alternative to cardiac surgery, or occlusion using coils.

Entities:  

Mesh:

Year:  2007        PMID: 17445336     DOI: 10.1017/S1047951107000510

Source DB:  PubMed          Journal:  Cardiol Young        ISSN: 1047-9511            Impact factor:   1.093


  13 in total

Review 1.  The Amplatzer Vascular Plug: Review of Evolution and Current Applications.

Authors:  Jorge E Lopera
Journal:  Semin Intervent Radiol       Date:  2015-12       Impact factor: 1.513

2.  Early experience on peripheral vascular application of the vascular plugs.

Authors:  Manoj Kumar Rohit; Alok Kumar Sinha; Naveen Krishna Kamana
Journal:  Indian Heart J       Date:  2013-09-05

3.  The Amplatzer vascular plug for large vessel occlusion in the endovascular management of aneurysms.

Authors:  Lakshmi A Ratnam; Richard M Walkden; Graham J Munneke; Robert A Morgan; Anna-Maria Belli
Journal:  Eur Radiol       Date:  2008-04-17       Impact factor: 5.315

4.  Transcatheter closure of abnormal vessels and arteriovenous fistulas with the Amplatzer vascular plug 4 in patients with congenital heart disease.

Authors:  Gesa Wiegand; Ludger Sieverding; Wolfgang Bocksch; Michael Hofbeck
Journal:  Pediatr Cardiol       Date:  2013-04-17       Impact factor: 1.655

5.  Transcatheter closure of a coronary fistula with an Amplatzer vascular plug: should a retrograde approach be standard?

Authors:  Seyed Ebrahim Kassaian; Mohammad Alidoosti; Hakimeh Sadeghian; Maria Raissi Dehkordi
Journal:  Tex Heart Inst J       Date:  2008

6.  Transarterial and transvenous approach for transcatheter closure of a large coronary artery fistula with the Amplatzer vascular plug.

Authors:  G Wiegand; L Sieverding; R Kaulitz; M Hofbeck
Journal:  Pediatr Cardiol       Date:  2008-07-25       Impact factor: 1.655

7.  Transcatheter closure of congenital coronary artery fistulae: immediate and long-term follow-up results.

Authors:  Xian-Yang Zhu; Duan-Zhen Zhang; Xiu-Min Han; Chun-Sheng Cui; Xiao-Tang Sheng; Qi-Guang Wang; Yong-Mei Cha; Prasad Abhiram; Charanjit S Rihal
Journal:  Clin Cardiol       Date:  2009-09       Impact factor: 2.882

8.  Transcatheter closure of a left circumflex coronary artery fistula in two children using the Amplatzer vascular plug.

Authors:  Chi-Di Liang; Sheung-Fat Ko; Ying-Jui Lin; Chih Yuan Fang
Journal:  Pediatr Cardiol       Date:  2009-11       Impact factor: 1.655

9.  Diagnosis and management of congenital coronary arteriovenous fistula in the pediatric patients presenting congestive heart failure and myocardial ischemia.

Authors:  Meng-Luen Lee; Ming Chen
Journal:  Yonsei Med J       Date:  2009-02-24       Impact factor: 2.759

10.  Percutaneous closure of a fistula from the left circumflex coronary artery to the coronary sinus in an infant.

Authors:  Yun Bao; Tian-Yuan Xiong; Xiao Li; Yuan Feng
Journal:  J Int Med Res       Date:  2021-06       Impact factor: 1.671

View more