Literature DB >> 17444553

Transvaginal sonographic measurement of cervical length vs. Bishop score in labor induction at term: tolerability and prediction of Cesarean delivery.

P C Tan1, N Vallikkannu, S Suguna, K F Quek, J Hassan.   

Abstract

OBJECTIVES: To compare transvaginal sonography for cervical length measurement and digital examination for Bishop score assessment in women undergoing labor induction at term, to assess their tolerability (in terms of pain) and ability to predict need for Cesarean delivery.
METHODS: A prospective study was performed on 249 women admitted for labor induction. Cervical length was measured using transvaginal ultrasound examination. A 10-point visual analog scale (VAS) for procedure-related pain was obtained. Bishop score was determined just before labor induction and another pain score was obtained. Delivery outcome was recorded. Analyses were by t-test, Fisher's exact test, receiver-operating characteristics (ROC) curves and multivariate logistic regression.
RESULTS: Transvaginal sonography was significantly less painful than digital examination for Bishop score assessment (mean difference in VAS score 3.46; P<0.001). Analyses of the ROC curves for cervical length and Bishop score indicated that both were predictors of Cesarean delivery (area under the curve 0.611 vs. 0.607; P=0.012 vs. P=0.015, respectively) with optimal cut-offs for predicting Cesarean delivery of >20 mm for cervical length and Bishop score<or=5. Cervical length had superior sensitivity (80% vs. 64%) and marginally better positive (30% vs. 27%) and negative (89% vs. 83%) predictive values. Multivariate logistic regression analysis revealed that only nulliparity (adjusted odds ratio (AOR) 4.1; 95% CI, 2.1-8.1; P<0.001) and transvaginal sonographic cervical length>20 mm (AOR 3.4; 95% CI, 1.4-8.1; P=0.006) were independent predictors of Cesarean delivery.
CONCLUSIONS: Transvaginal sonography for cervical length measurement is better tolerated than digital examination for Bishop score assessment. Both cervical length and Bishop score are useful predictors of the need for Cesarean delivery following labor induction. A cervical length>20 mm at labor induction at term is an independent predictor of Cesarean delivery. Copyright (c) 2007 ISUOG.

Entities:  

Mesh:

Year:  2007        PMID: 17444553     DOI: 10.1002/uog.4018

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  12 in total

1.  Manipal Cervical Scoring System by Transvaginal Ultrasound in Predicting Successful Labour Induction.

Authors:  Neha Bajpai; Rajesh Bhakta; Pratap Kumar; Lavanya Rai; Shripad Hebbar
Journal:  J Clin Diagn Res       Date:  2015-05-01

2.  Development and Validation of a Risk Prediction Model for Cesarean Delivery After Labor Induction.

Authors:  Valery A Danilack; Jennifer A Hutcheon; Elizabeth W Triche; David D Dore; Janet H Muri; Maureen G Phipps; David A Savitz
Journal:  J Womens Health (Larchmt)       Date:  2019-10-29       Impact factor: 2.681

3.  Role of Cervical Phosphorylated Insulin-Like Growth Factor-Binding Protein 1 (phIGFBP1) for Prediction of Successful Induction Among Primigravida with Prolonged Pregnancy.

Authors:  Aayushi Rathore; Richa Sharma; Rajarshi Kar; Anupama Tandon; Amita Suneja; Kiran Guleria
Journal:  J Obstet Gynaecol India       Date:  2020-09-25

Review 4.  Additional effects of the cervical length measurement in women with preterm contractions: a systematic review.

Authors:  Jolande Y Vis; Rosanna A Kuin; William A Grobman; Ben Willem J Mol; Patrick M M Bossuyt; Brent C Opmeer
Journal:  Arch Gynecol Obstet       Date:  2011-04-12       Impact factor: 2.344

5.  Sonographically accessed funneling of the uterine cervix as a predictor of successful labor induction.

Authors:  Seon Hwa Chung; Mi Kyung Kong; Eui Hyeok Kim; Sang Won Han
Journal:  Obstet Gynecol Sci       Date:  2015-05-19

Review 6.  Methods for assessing pre-induction cervical ripening.

Authors:  Ifeanyichukwu U Ezebialu; Ahizechukwu C Eke; George U Eleje; Chukwuemeka E Nwachukwu
Journal:  Cochrane Database Syst Rev       Date:  2015-06-12

7.  Pre-induction translabial ultrasound measurements in predicting mode of delivery compared to bishop score: a cross-sectional study.

Authors:  Soghra Khazardoost; Fahimeh Ghotbizadeh Vahdani; Sahar Latifi; Sedighe Borna; Maryam Tahani; Mohammad Ali Rezaei; Masoomeh Shafaat
Journal:  BMC Pregnancy Childbirth       Date:  2016-10-28       Impact factor: 3.007

8.  Cervical length measured by transvaginal ultrasonography versus Bishop score to predict successful labour induction in term pregnancies.

Authors:  Y J B Groeneveld; A M Bohnen; A M Van Heusden
Journal:  Facts Views Vis Obgyn       Date:  2010

9.  Predicting labor induction success by cervical funneling in uncomplicated pregnancies.

Authors:  Yoo-Na Kim; Ja Young Kwon; Eui Hyeok Kim
Journal:  J Obstet Gynaecol Res       Date:  2020-05-10       Impact factor: 1.730

10.  The Effect of Ultrasound-Measured Preinduction Cervical Length on Delivery Outcome in a Low-Resource Setting.

Authors:  Chidebe C Anikwe; Bartholomew C Okorochukwu; Emmanuel Uchendu; Cyril C Ikeoha
Journal:  ScientificWorldJournal       Date:  2020-05-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.