Literature DB >> 17441461

[Pentax-AWS improves laryngeal view compared with Macintosh blade during laryngoscopy and facilitates easier intubation].

Akihiro Suzuki1, Yuki Toyama, Norifumi Katsumi, Rika Sasaki, Koki Hirota, Hideki Matsumoto, Osamu Takahata, Hiroshi Iwasaki.   

Abstract

BACKGROUND: The PENTAX-AWS (AWS), combined with PBLADE is a novel tracheal intubation device which allows indirect visualization of the vocal cords without the alignment of the oral, pharyngeal axes required for direct laryngoscopy. Intubation procedure can be monitored on a built-in CCD monitor.
METHODS: We compared the laryngeal view obtained with the Macintosh laryngoscope with that obtained with the AWS in 100 patients scheduled for elective anesthesia. Laryngeal view was determined by Cormack & Lehane classification modified by Cook, first using the Macintosh laryngoscope with the patient's head and neck in the sniffing position, followed by the AWS with the head and neck in a neutral position. The time taken to pass the endotracheal tube, the incidence of tube impingement on the arytenoids and the total number of intubation attempts were also recorded.
RESULTS: The best laryngeal view obtained with the Macintosh laryngoscope in 100 cases were Grade I: 65, IIa: 16, IIb: 8, IIIa: 6, IIIb: 5, IV: 0. With AWS, the laryngeal views obtained were all grade I. The total time to pass the tube with the AWS was 19.5 +/- 7.9 s and the number of intubation attempts was 1.05 +/- 0.2. The Cormack grade obtained with the Macintosh laryngoscope did not affect the AWS view. The tube touched the right arytenoid in 5 cases but successful intubation was achieved by adjusting the blade direction.
CONCLUSIONS: We conclude that the PENTAX-AWS provides a better laryngeal view than the Macintosh laryngoscope and facilitates easier intubation under vision in a higher proportion of patients.

Entities:  

Mesh:

Year:  2007        PMID: 17441461

Source DB:  PubMed          Journal:  Masui        ISSN: 0021-4892


  3 in total

1.  Cardiovascular responses to tracheal intubation with the Airway Scope (Pentax-AWS).

Authors:  Akihiro Suzuki; Yuki Toyama; Norifumi Katsumi; Takayuki Kunisawa; John J Henderson; Hiroshi Iwasaki
Journal:  J Anesth       Date:  2008-02-27       Impact factor: 2.078

Review 2.  Optical and video laryngoscopes for emergency airway management.

Authors:  John C Sakles; Ross Rodgers; Samuel M Keim
Journal:  Intern Emerg Med       Date:  2008-02-15       Impact factor: 3.397

3.  Pentax-AWS (Airway Scope) and Airtraq: big difference between two similar devices.

Authors:  Akihiro Suzuki; Nobuko Abe; Tomoki Sasakawa; Takayuki Kunisawa; Osamu Takahata; Hiroshi Iwasaki
Journal:  J Anesth       Date:  2008-05-25       Impact factor: 2.078

  3 in total