Literature DB >> 17441248

An anatomically realistic lung model for Monte Carlo-based dose calculations.

Liang Liang1, Edward W Larsen, Indrin J Chetty.   

Abstract

Treatment planning for disease sites with large variations of electron density in neighboring tissues requires an accurate description of the geometry. This self-evident statement is especially true for the lung, a highly complex organ having structures with a wide range of sizes that range from about 10(-4) to 1 cm. In treatment planning, the lung is commonly modeled by a voxelized geometry obtained using computed tomography (CT) data at various resolutions. The simplest such model, which is often used for QA and validation work, is the atomic mix or mean density model, in which the entire lung is homogenized and given a mean (volume-averaged) density. The purpose of this paper is (i) to describe a new heterogeneous random lung model, which is based on morphological data of the human lung, and (ii) use this model to assess the differences in dose calculations between an actual lung (as represented by our model) and a mean density (homogenized) lung. Eventually, we plan to use the random lung model to assess the accuracy of CT-based treatment plans of the lung. For this paper, we have used Monte Carlo methods to make accurate comparisons between dose calculations for the random lung model and the mean density model. For four realizations of the random lung model, we used a single photon beam, with two different energies (6 and 18 MV) and four field sizes (1 x 1, 5 x 5, 10 x 10, and 20 x 20 cm2). We found a maximum difference of 34% of D(max) with the 1 x 1, 18 MV beam along the central axis (CAX). A "shadow" region distal to the lung, with dose reduction up to 7% of D(max), exists for the same realization. The dose perturbations decrease for larger field sizes, but the magnitude of the differences in the shadow region is nearly independent of the field size. We also observe that, compared to the mean density model, the random structures inside the heterogeneous lung can alter the shape of the isodose lines, leading to a broadening or shrinking of the penumbra region. For small field sizes, the mean lung doses significantly depend on the structures' relative locations to the beam. In addition to these comparisons between the random lung and mean density models, we also provide a preliminary comparison between dose calculations for the random lung model and a voxelized version of this model at 0.4 x 0.4 x 0.4 cm3 resolution. Overall, this study is relevant to treatment planning for lung tumors, especially in situations where small field sizes are used. Our results show that for such situations, the mean density model of the lung is inadequate, and a more accurate CT model of the lung is required. Future work with our model will involve patient motion, setup errors, and recommendations for the resolution of CT models.

Entities:  

Mesh:

Year:  2007        PMID: 17441248     DOI: 10.1118/1.2437284

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  The effect of disease and respiration on airway shape in patients with moderate persistent asthma.

Authors:  Spyridon Montesantos; Ira Katz; Jose Venegas; Marine Pichelin; Georges Caillibotte
Journal:  PLoS One       Date:  2017-07-31       Impact factor: 3.240

2.  3D-printable lung phantom for distal falloff verification of proton Bragg peak.

Authors:  Junichi Koketsu; Hiroaki Kumada; Kenta Takada; Hideyuki Takei; Yutaro Mori; Satoshi Kamizawa; Yuchao Hu; Hideyuki Sakurai; Takeji Sakae
Journal:  J Appl Clin Med Phys       Date:  2019-09       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.