Literature DB >> 17439830

Influence of blood collection systems on the prothrombin time and international sensitivity index determined with human and rabbit thromboplastin reagents.

Anton M H P van den Besselaar1, Martha M C L Hoekstra, Evelina Witteveen, Jan H Didden, Felix J M van der Meer.   

Abstract

Three brands of blood collection tubes were studied for their influence on the prothrombin time (PT) and international sensitivity index (ISI) for 5 commercial thromboplastin reagents. With all reagents, PTs were shorter in Vacutainer (Becton Dickinson Vacutainer Systems, Plymouth, England) samples than in S-Monovette (Sarstedt, Nümbrecht, Germany) or Venosafe (Terumo Europe, Leuven, Belgium) samples. ISI values were higher with Vacutainer samples than with S-Monovette or Venosafe samples. The ISI differences between the tubes were small for Thromborel-S (2.1%; Dade Behring, Marburg, Germany) and Hepato Quick (1.1%; Diagnostica Stago, Asnières, France; Roche Diagnostics Nederland, Almere, the Netherlands) but greater for Neoplastin Plus (5.5%; Diagnostica Stago; Roche Diagnostics Nederland), Simplastin HTF (8.3%; bioMérieux, Durham, NC), and Innovin (8.8%; Dade Behring). The PT and ISI differences between the tubes could be explained mostly by the effect of magnesium ion contamination in the sodium citrate solutions. When PT ratios were transformed into international normalized ratios (INRs) using crossover ISI (ie, samples collected with one type of tube and ISI determined with another collection system for the PT reagent), the differences in mean INRs could be approximately 10%. For ISI calibration of reference thromboplastins, blood collection tubes should be used with minimal divalent metal ion contamination of the citrate solution.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17439830     DOI: 10.1309/NW194EAMD4WMEHJD

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  3 in total

1.  Magnesium and Hemorrhage Volume in Patients With Aneurysmal Subarachnoid Hemorrhage.

Authors:  Eric M Liotta; Ameeta Karmarkar; Ayush Batra; Minjee Kim; Shyam Prabhakaran; Andrew M Naidech; Matthew B Maas
Journal:  Crit Care Med       Date:  2020-01       Impact factor: 7.598

2.  Magnesium, hemostasis, and outcomes in patients with intracerebral hemorrhage.

Authors:  Eric M Liotta; Shyam Prabhakaran; Rajbeer S Sangha; Robin A Bush; Alan E Long; Stephen A Trevick; Matthew B Potts; Babak S Jahromi; Minjee Kim; Edward M Manno; Farzaneh A Sorond; Andrew M Naidech; Matthew B Maas
Journal:  Neurology       Date:  2017-07-26       Impact factor: 9.910

3.  Influence of blood collection systems on coagulation tests.

Authors:  Soner Yavaş; Selime Ayaz; S Kenan Köse; Fatma Ulus; A Tulga Ulus
Journal:  Turk J Haematol       Date:  2012-12-05       Impact factor: 1.831

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.