Literature DB >> 1743732

Information contained in sensory nerve recordings made with intrafascicular electrodes.

E V Goodall1, T M Lefurge, K W Horch.   

Abstract

Multiunit recordings were made in anesthetized cats with chronically implanted intrafascicular electrodes over a period of six months. Neural signals recorded with these electrodes consisted of activity in sensory fibers innervating a variety of cutaneous mechanoreceptors. Mechanical stimuli were used to selectively activate individual nerve fibers, and the receptive field and receptor type were identified for each unit. Over a period of six months, there was a net shift in the recorded population, but the electrodes continued to provide a representative sample of the activity in the fascicle as a whole. The total number of units from which activity could be recorded remained roughly constant with time, and individual units persisted in the recordings for up to six months. These results indicate that intrafascicular electrodes could be used to sample information carried by individual somatosensory fibers on a long term basis.

Entities:  

Mesh:

Year:  1991        PMID: 1743732     DOI: 10.1109/10.83604

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  6 in total

1.  Chronically implanted intrafascicular recording electrodes.

Authors:  T Lefurge; E Goodall; K Horch; L Stensaas; A Schoenberg
Journal:  Ann Biomed Eng       Date:  1991       Impact factor: 3.934

2.  Analysis of single-unit firing patterns in multi-unit intrafascicular recordings.

Authors:  E V Goodall; K W Horch; T G McNaughton; C M Lybbert
Journal:  Med Biol Eng Comput       Date:  1993-05       Impact factor: 2.602

Review 3.  Bionic intrafascicular interfaces for recording and stimulating peripheral nerve fibers.

Authors:  Ranu Jung; James J Abbas; Sathyakumar Kuntaegowdanahalli; Anil K Thota
Journal:  Bioelectron Med (Lond)       Date:  2017-12-14

4.  Reduced fatigue in electrically stimulated muscle using dual channel intrafascicular electrodes with interleaved stimulation.

Authors:  K Yoshida; K Horch
Journal:  Ann Biomed Eng       Date:  1993 Nov-Dec       Impact factor: 3.934

Review 5.  On the viability of implantable electrodes for the natural control of artificial limbs: review and discussion.

Authors:  Max Ortiz-Catalan; Rickard Brånemark; Bo Håkansson; Jean Delbeke
Journal:  Biomed Eng Online       Date:  2012-06-20       Impact factor: 2.819

Review 6.  Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics.

Authors:  Emil H Rijnbeek; Nick Eleveld; Wouter Olthuis
Journal:  Front Neurosci       Date:  2018-05-28       Impact factor: 4.677

  6 in total