Literature DB >> 17435517

Oxygen demands with hybrid contact lenses.

Ben Pilskalns1, Barbara A Fink, Richard M Hill.   

Abstract

PURPOSE: The purpose of this study was to assess the corneal response, as measured by corneal oxygen uptake, of keratoconic corneas to SoftPerm and SynergEyes hybrid contact lenses at the central cornea, 2.0 and 4.5 mm temporal to the central cornea, and 1 mm temporal to the limbus.
METHODS: Corneal oxygen uptake rates were measured with a Clark-type polarographic electrode on the right eyes of 14 subjects and the left eye of 1 subject, all with keratoconus. Measurements were made at the central cornea, 2.0 and 4.5 mm temporal to the central cornea, and 1 mm temporal to the limbus. They were made for the open eye condition, as well as following 300 s of SoftPerm and SynergEyes hybrid contact lens wear. A one-way analysis of variance (ANOVA) was used to determine the effect of measurement location on oxygen uptake rates under uncovered eye conditions. To determine the difference among oxygen uptake rates relative to those of the uncovered eye at each measurement location for each hybrid lens, a two-way repeated measures ANOVA was used. Multiple comparisons with Tukey-Kramer adjustment were used post hoc to determine which locations were significantly different.
RESULTS: For the uncovered keratoconic cornea, there was no significant difference among the oxygen uptake rates associated with the three corneal locations; however, the oxygen uptake rates measured 1 mm temporal to the limbus were significantly higher than those measured at the three corneal locations. Comparison of oxygen uptake rates measured with the SoftPerm and SynergEyes lenses relative to those of the uncovered eye at each location revealed significantly higher rates at the peripheral cornea than at the central cornea. At all locations, the relative oxygen uptake rates obtained with the SynergEyes lenses were lower than those obtained with the SoftPerm lenses.
CONCLUSIONS: The SynergEyes lens allows significantly more oxygen to reach the cornea during wear than the SoftPerm lens at the central cornea, as well as 2.0 mm and 4.5 mm temporal to the central cornea.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17435517     DOI: 10.1097/OPX.0b013e3180421748

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  9 in total

Review 1.  [Keratoconus lenses: the small correction miracle].

Authors:  U Klühspies; A Grunder; S Goebels; F Schirra; B Seitz
Journal:  Ophthalmologe       Date:  2013-09       Impact factor: 1.059

Review 2.  Current perspectives in the management of keratoconus with contact lenses.

Authors:  Li Lim; Elizabeth Wen Ling Lim
Journal:  Eye (Lond)       Date:  2020-07-08       Impact factor: 3.775

3.  The impact of hybrid contact lenses on keratoconus progression after accelerated transepithelial corneal cross-linking.

Authors:  Mehmet Gökhan Aslan; Hüseyin Fındık; Murat Okutucu; Emre Aydın; Feyzahan Uzun
Journal:  Int Ophthalmol       Date:  2020-08-27       Impact factor: 2.031

Review 4.  Nonsurgical Procedures for Keratoconus Management.

Authors:  L Rico-Del-Viejo; M Garcia-Montero; J L Hernández-Verdejo; S García-Lázaro; F J Gómez-Sanz; A Lorente-Velázquez
Journal:  J Ophthalmol       Date:  2017-12-21       Impact factor: 1.909

Review 5.  Keratoconus Treatment Algorithm.

Authors:  Konstantinos D Andreanos; Kate Hashemi; Myrsini Petrelli; Konstantinos Droutsas; Ilias Georgalas; George D Kymionis
Journal:  Ophthalmol Ther       Date:  2017-07-28

6.  A comparison of the visual acuity outcome between Clearkone and RGP lenses.

Authors:  Mohammadali Hassani; Ebrahim Jafarzadehpur; Ali Mirzajani; AbbasAli Yekta; Mehdi Khabazkhoob
Journal:  J Curr Ophthalmol       Date:  2017-08-26

Review 7.  Updates on Managements for Keratoconus.

Authors:  Mehrdad Mohammadpour; Zahra Heidari; Hassan Hashemi
Journal:  J Curr Ophthalmol       Date:  2017-12-06

Review 8.  Contact lens in keratoconus.

Authors:  Varsha M Rathi; Preeji S Mandathara; Srikanth Dumpati
Journal:  Indian J Ophthalmol       Date:  2013-08       Impact factor: 1.848

9.  Estimation of the hybrid lens parameters through rigid gas permeable lens fitting.

Authors:  Mohammadali Hasani; Hassan Hashemi; Ebrahim Jafarzadehpur; Abbas Ali Yekta; Nooshin Dadbin; Mehdi Khabazkhoob
Journal:  J Curr Ophthalmol       Date:  2016-06-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.