Literature DB >> 17433406

Removal of particle-associated bacteriophages by dual-media filtration at different filter cycle stages and impacts on subsequent UV disinfection.

Michael R Templeton1, Robert C Andrews, Ron Hofmann.   

Abstract

This bench-scale study investigated the passage of particle-associated bacteriophage through a dual-media (anthracite-sand) filter over a complete filter cycle and the effect on subsequent ultraviolet (UV) disinfection. Two model viruses, bacteriophages MS2 and T4, were considered. The water matrix was de-chlorinated tap water with either kaolin or Aldrich humic acid (AHA) added and coagulated with alum to form floc before filtration. The turbidity of the influent flocculated water was 6.4+/-1.5 NTU. Influent and filter effluent turbidity and particle counts were measured as well as headloss across the filter media. Filter effluent samples were collected for phage enumeration during three filter cycle stages: (i) filter ripening; (ii) stable operation; and (iii) end of filter cycle. Stable filter operation was defined according to a filter effluent turbidity goal of <0.3 NTU. Influent and filter effluent samples were subsequently exposed to UV light (254 nm) at 40 mJ/cm(2) using a low pressure UV collimated beam. The study found statistically significant differences (alpha=0.05) in the quantity of particle-associated phage present in the filter effluent during the three stages of filtration. There was reduced UV disinfection efficiency due to the presence of particle-associated phage in the filter effluent in trials with bacteriophage MS2 and humic acid floc. Unfiltered influent water samples also resulted in reduced UV inactivation of phage relative to particle-free control conditions for both phages. Trends in filter effluent turbidity corresponded with breakthrough of particle-associated phage in the filter effluent. The results therefore suggest that maintenance of optimum filtration conditions upstream of UV disinfection is a critical barrier to particle-associated viruses.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17433406     DOI: 10.1016/j.watres.2007.02.047

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  3 in total

Review 1.  Inadequately treated wastewater as a source of human enteric viruses in the environment.

Authors:  Anthony I Okoh; Thulani Sibanda; Siyabulela S Gusha
Journal:  Int J Environ Res Public Health       Date:  2010-06-14       Impact factor: 3.390

2.  Performance evaluation of different filter media in turbidity removal from water by application of modified qualitative indices.

Authors:  G Badalians Gholikandi; E Dehghanifard; M Noori Sepehr; A Torabian; S Moalej; A Dehnavi; Ar Yari; Ar Asgari
Journal:  Iran J Public Health       Date:  2012-04-30       Impact factor: 1.429

Review 3.  Pathogen and Particle Associations in Wastewater: Significance and Implications for Treatment and Disinfection Processes.

Authors:  C Chahal; B van den Akker; F Young; C Franco; J Blackbeard; P Monis
Journal:  Adv Appl Microbiol       Date:  2016-09-15       Impact factor: 5.515

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.