Root cause analysis of laboratory turnaround times for patients in the emergency department.

Christopher M B Fernandes1, Andrew Worster, Stephen Hill, Catherine McCallum, Kevin Eva.   

Abstract

INTRODUCTION: Laboratory investigations are essential to patient care and are conducted routinely in emergency departments (EDs). This study reports the turnaround times at an academic, tertiary care ED, using root cause analysis to identify potential areas of improvement. Our objectives were to compare the laboratory turnaround times with established benchmarks and identify root causes for delays.
METHODS: Turnaround and process event times for a consecutive sample of hemoglobin and potassium measurements were recorded during an 8-day study period using synchronized time stamps. A log transformation (ln [minutes + 1]) was performed to normalize the time data, which were then compared with established benchmarks using one-sample t tests.
RESULTS: The turnaround time for hemoglobin was significantly less than the established benchmark (n = 140, t = -5.69, p < 0.001) and that of potassium was significantly greater (n = 121, t = 12.65, p < 0.001). The hemolysis rate was 5.8%, with 0.017% of samples needing recollection. Causes of delays included order-processing time, a high proportion (43%) of tests performed on patients who had been admitted but were still in the ED waiting for a bed, and excessive laboratory process times for potassium.
CONCLUSIONS: The turnaround time for hemoglobin (18 min) met the established benchmark, but that for potassium (49 min) did not. Root causes for delay were order-processing time, excessive queue and instrument times for potassium and volume of tests for admitted patients. Further study of these identified causes of delays is required to see whether laboratory TATs can be reduced.

Entities:  

Year:  2004        PMID: 17433161     DOI: 10.1017/s1481803500009088

Source DB:  PubMed          Journal:  CJEM        ISSN: 1481-8035            Impact factor:   2.410


  3 in total

Review 1.  Current Methods of Haemolysis Detection and Reporting as a Source of Risk to Patient Safety: a Narrative Review.

Authors:  Euan J McCaughey; Elia Vecellio; Rebecca Lake; Ling Li; Leslie Burnett; Douglas Chesher; Stephen Braye; Mark Mackay; Stephanie Gay; Tony C Badrick; Johanna I Westbrook; Andrew Georgiou
Journal:  Clin Biochem Rev       Date:  2016-12

Review 2.  Mapping turnaround times (TAT) to a generic timeline: a systematic review of TAT definitions in clinical domains.

Authors:  Bernhard Breil; Fleur Fritz; Volker Thiemann; Martin Dugas
Journal:  BMC Med Inform Decis Mak       Date:  2011-05-24       Impact factor: 2.796

3.  Does Elimination of a Laboratory Sample Clotting Stage Requirement Reduce Overall Turnaround Times for Emergency Department Stat Biochemical Testing?

Authors:  Sarah Compeau; Michael Howlett; Stephanie Matchett; Jennifer Shea; Jacqueline Fraser; Rose McCloskey; Paul Atkinson
Journal:  Cureus       Date:  2016-10-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.