Literature DB >> 17431787

Methods for three-dimensional geometric characterization of the arterial vasculature.

Padraig M O'Flynn1, Gerard O'Sullivan, Abhay S Pandit.   

Abstract

Complex vascular anatomy often affects endovascular procedural outcome. Accurate quantitative assessment of three-dimensional (3D) in-vivo arterial morphology is therefore vital for endovascular device design, and preoperative planning of percutaneous interventions. The aim of this work was to establish geometric parameters describing arterial branch origin, trajectory, and vessel curvature in 3D space that eliminate the errors implicit in planar measurements. 3D branching parameters at visceral and aortic bifurcation sites, as well as arterial tortuosity were determined from vessel centerlines derived from magnetic resonance angiography data for three subjects. Errors in coronal measurements of 3D branching angles for the right and left renal arteries were 3.1 +/- 3.4 degrees and 7.5 +/- 3.7 degrees , respectively. Distortion of the anterior visceral branching angles from sagittal measurements was less pronounced. Asymmetry in branching and planarity of the common iliac arteries was observed at aortic bifurcations. The renal arteries possessed considerably greater 3D curvature than the abdominal aorta and common iliac vessels with mean average values of 0.114 +/- 0.015 and 0.070 +/- 0.019 mm(-1) for the left and right, respectively. In conclusion, planar projections misrepresented branch trajectory, vessel length, and tortuosity proving the importance of 3D geometric characterization for possible applications in planning of endovascular interventional procedures and providing parameters for endovascular device design.

Mesh:

Year:  2007        PMID: 17431787     DOI: 10.1007/s10439-007-9307-9

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  12 in total

1.  Extraction of morphometry and branching angles of porcine coronary arterial tree from CT images.

Authors:  Thomas Wischgoll; Jenny S Choy; Ghassan S Kassab
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-09-11       Impact factor: 4.733

2.  In vivo deformation of the human abdominal aorta and common iliac arteries with hip and knee flexion: implications for the design of stent-grafts.

Authors:  Gilwoo Choi; Lewis K Shin; Charles A Taylor; Christopher P Cheng
Journal:  J Endovasc Ther       Date:  2009-10       Impact factor: 3.487

3.  Development of a quantitative intracranial vascular features extraction tool on 3D MRA using semiautomated open-curve active contour vessel tracing.

Authors:  Li Chen; Mahmud Mossa-Basha; Niranjan Balu; Gador Canton; Jie Sun; Kristi Pimentel; Thomas S Hatsukami; Jenq-Neng Hwang; Chun Yuan
Journal:  Magn Reson Med       Date:  2017-10-17       Impact factor: 4.668

4.  Three-dimensional geometry of the human carotid artery.

Authors:  Alexey V Kamenskiy; Jason N MacTaggart; Iraklis I Pipinos; Jai Bikhchandani; Yuris A Dzenis
Journal:  J Biomech Eng       Date:  2012-06       Impact factor: 2.097

5.  Neurovascular modeling: small-batch manufacturing of silicone vascular replicas.

Authors:  J Y Chueh; A K Wakhloo; M J Gounis
Journal:  AJNR Am J Neuroradiol       Date:  2009-03-25       Impact factor: 3.825

6.  Digital reconstruction and morphometric analysis of human brain arterial vasculature from magnetic resonance angiography.

Authors:  Susan N Wright; Peter Kochunov; Fernando Mut; Maurizio Bergamino; Kerry M Brown; John C Mazziotta; Arthur W Toga; Juan R Cebral; Giorgio A Ascoli
Journal:  Neuroimage       Date:  2013-05-28       Impact factor: 6.556

7.  Oxygen mass transfer in a model three-dimensional artery.

Authors:  G Coppola; C Caro
Journal:  J R Soc Interface       Date:  2008-09-06       Impact factor: 4.118

8.  Validation of an arterial tortuosity measure with application to hypertension collection of clinical hypertensive patients.

Authors:  Karl T Diedrich; John A Roberts; Richard H Schmidt; Chang-Ki Kang; Zang-Hee Cho; Dennis L Parker
Journal:  BMC Bioinformatics       Date:  2011-10-18       Impact factor: 3.169

Review 9.  Swirling Flow and Wall Shear: Evaluating the BioMimics 3D Helical Centerline Stent for the Femoropopliteal Segment.

Authors:  Timothy M Sullivan; Thomas Zeller; Masato Nakamura; Colin G Caro; Michael Lichtenberg
Journal:  Int J Vasc Med       Date:  2018-02-26

10.  Semi-automatic measurements and description of the geometry of vascular tree based on Bézier spline curves: application to cerebral arteries.

Authors:  Jarosław Żyłkowski; Grzegorz Rosiak; Dominik Spinczyk
Journal:  Biomed Eng Online       Date:  2018-08-29       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.