Literature DB >> 17431780

New type of artificial liver support system (ALSS) using the photocatalytic effect of titanium oxide.

Hisamitsu Shinohara1, Mitsuo Shimada, Tetsuya Ikemoto, Yuji Morine, Satoru Imura, Masahiko Fujii, Takahumi Imaizumi, Michio Murayama, Yoshiro Aiba.   

Abstract

Although various types of artificial liver support systems (ALSSs) including a hybrid type have been made, few are practical ALSSs for treatment of acute and/or chronic hepatic failure. Titanium oxide (TiO(2)), a stable material, dismantles various materials using a photocatalytic action under ultraviolet irradiation. The aim of this study was to assess the effect of a new ALSS using TiO(2). Hepatic failure plasma obtained from patients undergoing plasma exchange therapy due to acute liver failure was used in these experiments. The plasma was perfused using a closed circuit model with a column filled with TiO(2). The plasma concentrations of total bilirubin, albumin, fibrinogen, interleukin (IL)-6, IL-8, and IL-10 were serially measured. We evaluated the photocatalytic effect of TiO(2) irradiated with ultraviolet light. The effect of initial perfusion with fresh-frozen plasma (FFP) was also investigated, focusing on the decrease in fibrinogen during perfusion. Levels of total bilirubin decreased after perfusion using the column filled with TiO(2), compared with no UV irradiation. The levels of IL-6, IL-8, and IL-10 decreased after perfusion using the TiO(2) device. The albumin level was maintained at the initial level, however, the fibrinogen level decreased within 4 hr. Initial perfusion of the circuit with FFP improved the decrease in fibrinogen for up to 8 hr. Our new perfusion device using the photocatalytic action of TiO(2) may be a promising ALSS.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17431780     DOI: 10.1007/s10620-006-9701-4

Source DB:  PubMed          Journal:  Dig Dis Sci        ISSN: 0163-2116            Impact factor:   3.199


  15 in total

1.  Prognostic value of cytokines in SIRS general medical patients.

Authors:  M Rodríguez-Gaspar; F Santolaria; A Jarque-López; E González-Reimers; A Milena; M J de la Vega; E Rodríguez-Rodríguez; J L Gómez-Sirvent
Journal:  Cytokine       Date:  2001-08-21       Impact factor: 3.861

Review 2.  Artificial and bioartificial support systems for acute and acute-on-chronic liver failure: a systematic review.

Authors:  Lise L Kjaergard; Jianping Liu; Bodil Als-Nielsen; Christian Gluud
Journal:  JAMA       Date:  2003-01-08       Impact factor: 56.272

3.  Application of Molecular Adsorbents Recirculating System to remove NO and cytokines in severe liver failure patients with multiple organ dysfunction syndrome.

Authors:  Li-Min Guo; Jing-Yuan Liu; Dao-Zhen Xu; Bao-Shun Li; Hao Han; Ling-Hang Wang; Wei-Yan Zhang; Lian-He Lu; Xia Guo; Feng-Xia Sun; Hong-Yu Zhang; Xiao-Dong Liu; Jian-Ping Zhang; Yun Yao; Zhong-Ping He; Min-Min Wang
Journal:  Liver Int       Date:  2003       Impact factor: 5.828

Review 4.  Artificial liver support: future aspects.

Authors:  Katsutoshi Naruse
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

5.  Liver support by extracorporeal blood purification: a clinical observation.

Authors:  J Stange; S R Mitzner; S Klammt; J Freytag; P Peszynski; J Loock; H Hickstein; G Korten; R Schmidt; J Hentschel; M Schulz; M Löhr; S Liebe; W Schareck; U T Hopt
Journal:  Liver Transpl       Date:  2000-09       Impact factor: 5.799

6.  Bioartificial liver: current status.

Authors:  G Pless; I M Sauer
Journal:  Transplant Proc       Date:  2005-11       Impact factor: 1.066

7.  Prospective, randomized, multicenter, controlled trial of a bioartificial liver in treating acute liver failure.

Authors:  Achilles A Demetriou; Robert S Brown; Ronald W Busuttil; Jeffrey Fair; Brendan M McGuire; Philip Rosenthal; Jan Schulte Am Esch; Jan Lerut; Scott L Nyberg; Mauro Salizzoni; Elizabeth A Fagan; Bernard de Hemptinne; Christoph E Broelsch; Maurizio Muraca; Joan Manuel Salmeron; John M Rabkin; Herold J Metselaar; Daniel Pratt; Manuel De La Mata; Lawrence P McChesney; Gregory T Everson; Philip T Lavin; Anthony C Stevens; Zorina Pitkin; Barry A Solomon
Journal:  Ann Surg       Date:  2004-05       Impact factor: 12.969

8.  Development of a hybrid bioartificial liver.

Authors:  J Rozga; M D Holzman; M S Ro; D W Griffin; D F Neuzil; T Giorgio; A D Moscioni; A A Demetriou
Journal:  Ann Surg       Date:  1993-05       Impact factor: 12.969

9.  Photocatalytic killing effect of TiO2 nanoparticles on Ls-174-t human colon carcinoma cells.

Authors:  Ai-Ping Zhang; Yan-Ping Sun
Journal:  World J Gastroenterol       Date:  2004-11-01       Impact factor: 5.742

10.  Assessment of resin perfusion in hepatic failure in vitro and in vivo.

Authors:  Ying-Jie Wang; Ze-Wen Wang; Bing-Wei Luo; Hong-Ling Liu; Hong-Wei Wen
Journal:  World J Gastroenterol       Date:  2004-03-15       Impact factor: 5.742

View more
  1 in total

Review 1.  Bioartificial liver devices: Perspectives on the state of the art.

Authors:  Yi-Tao Ding; Xiao-Lei Shi
Journal:  Front Med       Date:  2010-11-19       Impact factor: 4.592

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.