Three-dimensional ultrasound fetal urinary bladder volume measurement: reliability of rotational (VOCAL) technique using different steps of rotation.

F M Peixoto-Filho1, R A M Sá, L M Lopes, L G C Velarde, E Marchiori, Y Ville.   

Abstract

OBJECTIVE: The aim of the study was to investigate the inter- and intraobserver reliability in measuring the fetal bladder volume by 3d ultrasound imaging by VOCAL. In addition a comparison of 15 degrees and 30 degrees rotation steps calculation had been performed.
METHODS: Measurements (n = 240) of FB volume were performed in 30 low-risk patients with gestation times ranging from 22 to 39 weeks by two independent observers blind to each other. All fetuses were examined and no ultrasound detectable malformation was found. The volume for each FB was measured twice by the observers who used the Virtual Organ Computed-aided Analysis (VOCAL) technique. Distinct sets of 12 and 6 planes were obtained after sequential rotations of 15 degrees and 30 degrees, respectively. The internal contour of fetal bladder was determined manually and carefully as to exclude adjacent structures from volume calculation. Wilcoxon signed-rank test was used for the comparison of paired samples in the cases of replication within and between observers. Spearman's rank correlation was used to study the relationship among angles. Bland and Altman's graphical approach was used to investigate the agreement between observers.
RESULTS: Both techniques were shown to be highly reliable. No significant difference was found between the measurements of FB volume with the VOCAL technique by varying either the steps of rotation or the observers.
CONCLUSION: Excellent correlations were found for both observers in the use of rotation angles of 15 degrees and 30 degrees . Since a significantly faster evaluation was obtained by using a 30 degrees rotation step it must be preferred to assess the FB volume. Our results show that the VOCAL technique, with a plane rotation of 30 degrees , can be used in a simple way to estimate fetal urine production.

Entities:  

Mesh:

Year:  2007        PMID: 17431648     DOI: 10.1007/s00404-007-0360-2

Source DB:  PubMed          Journal:  Arch Gynecol Obstet        ISSN: 0932-0067            Impact factor:   2.344


  8 in total

1.  Bladder volume correction factors measured with 3D ultrasound and BladderScan.

Authors:  Naomi N Vinod; Anna S Nagle; Hameeda A Naimi; Hiren Kolli; Derek Sheen; Naveen Nandanan; Laura R Carucci; John E Speich; Adam P Klausner
Journal:  Can J Urol       Date:  2019-08       Impact factor: 1.344

2.  Intra-observer repeatability when assessing the foetal urinary bladder volume by the Virtual Organ Computer-aided AnaLysis and SUM-OF-CYLINDERS methods: A pilot study.

Authors:  Mats A Fagerquist; Vivek Sethi; Eli Skytteren; Anders Oden
Journal:  Ultrasound       Date:  2017-05-23

3.  Antenatal ultrasonographic anteroposterior renal pelvis diameter measurement: is it a reliable way of defining fetal hydronephrosis?

Authors:  Alamanda Kfoury Pereira; Zilma Silveira Nogueira Reis; Maria Cândida Ferrarez Bouzada; Eduardo Araújo de Oliveira; Gabriel Osanan; Antônio Carlos Vieira Cabral
Journal:  Obstet Gynecol Int       Date:  2011-05-17

4.  Estimation of uterine volume: A comparison between Viewpoint and 3D ultrasound estimation in women undergoing laparoscopic hysterectomy.

Authors:  Ishwari Casikar; Max Mongelli; Shannon Reid; George Condous
Journal:  Australas J Ultrasound Med       Date:  2015-12-31

5.  Comparison of 2D and 3D ultrasound methods to measure serial bladder volumes during filling: Steps toward development of non-invasive ultrasound urodynamics.

Authors:  Anna S Nagle; Rachel J Bernardo; Jary Varghese; Laura R Carucci; Adam P Klausner; John E Speich
Journal:  Bladder (San Franc)       Date:  2018-01-04

6.  Quantification of Fetal Renal Function Using Fetal Urine Production Rate and Its Reflection on the Amniotic and Fetal Creatinine Levels During Pregnancy.

Authors:  Udoamaka Ezuruike; Alexander Blenkinsop; Amita Pansari; Khaled Abduljalil
Journal:  Front Pediatr       Date:  2022-03-03       Impact factor: 3.418

7.  Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method.

Authors:  Sung-Hye You; Sang-Il Suh; In-Seon Ryoo; Gyu-Ri Son; Young-Hen Lee; Hyung Suk Seo; Nam Joon Lee; Hae Young Seol
Journal:  Ultrasonography       Date:  2016-06-08

8.  Z-scores of fetal bladder size for antenatal differential diagnosis between posterior urethral valves and urethral atresia.

Authors:  F Fontanella; H Groen; L K Duin; S Suresh; C M Bilardo
Journal:  Ultrasound Obstet Gynecol       Date:  2021-12       Impact factor: 8.678

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.