Literature DB >> 17429122

Intra-operative Iso-C3D navigation for pedicle screw instrumentation of hangman's fracture: a case report.

S Rajasekaran1, S Vidyadhara, A P Shetty.   

Abstract

Pedicle screw instrumentation of the upper cervical spine is rarely performed in trauma surgery because of the risk of damaging neurovascular structures. We report successful treatment of an unstable hangman's fracture with posterior pedicle screw fixation using Iso-C3D fluoroscopy-based computer navigation guidance. Postoperative computed tomographic images confirmed accurate placement of the pedicle screws. The navigation system is useful, especially in an unstable upper cervical spine injury where the likelihood of change in the inter-segmental relationship is maximal before and after positioning for surgery. The navigation system has the advantage of data acquisition after patient positioning, thus making safe pedicle fixation of the C1 and C2 vertebrae possible despite fractured posterior elements.

Entities:  

Mesh:

Year:  2007        PMID: 17429122     DOI: 10.1177/230949900701500116

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  6 in total

1.  Real-time imaging with the o-arm for skull base applications: a cadaveric feasibility study.

Authors:  Shaan M Raza; Alfred P See; Michael Lim
Journal:  J Neurol Surg B Skull Base       Date:  2012-10

Review 2.  Image-guided spine surgery: state of the art and future directions.

Authors:  Thorsten Tjardes; Sven Shafizadeh; Dieter Rixen; Thomas Paffrath; Bertil Bouillon; Eva S Steinhausen; Holger Baethis
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

3.  Role of intraoperative Iso-C based navigation in challenging spine trauma.

Authors:  Ashish Jaiswal; Ajoy P Shetty; S Rajasekaran
Journal:  Indian J Orthop       Date:  2007-10       Impact factor: 1.251

Review 4.  Traumatic Spondylolisthesis of the Axis Vertebra in Adults.

Authors:  Philipp Schleicher; Matti Scholz; Andreas Pingel; Frank Kandziora
Journal:  Global Spine J       Date:  2015-04-29

5.  Determination of detection depth of optical probe in pedicle screw measurement device.

Authors:  Weitao Li; Yangyang Liu; Zhiyu Qian
Journal:  Biomed Eng Online       Date:  2014-11-01       Impact factor: 2.819

6.  Transpedicular direct osteosynthesis of hangman's fracture from a mini-open exposure as a less invasive procedure: A technical note.

Authors:  Viktor Zsolt Kovari; Attila Josvai; Andras Csokay
Journal:  Trauma Case Rep       Date:  2017-11-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.