Literature DB >> 17429121

Computed tomographic evaluation of the odontoid process for two-screw fixation in type-II fracture: a Malaysian perspective.

M I Yusof1, A H Yusof, M S Abdullah, T M A R Hussin.   

Abstract

PURPOSES: To measure the diameter of the odontoid process in a Malaysian population using computed tomographic (CT) scan and determine the feasibility of treating type-II odontoid fractures using 2 cortical screws.
METHODS: CT images of the odontoid process of 85 patients aged 18 to 80 years were analysed; 69 (81%) were male (mean age, 44 years) and 16 (19%) were female (mean age, 48 years). Both anteroposterior (AP) and transverse diameters of the odontoid process were measured via axial CT images at 3 different levels: the base of the odontoid process and 1.2 mm and 2.4 mm above the base.
RESULTS: The mean AP and transverse diameters of the odontoid process in men were 11.3 (range, 10.0-12.6; standard deviation [SD], 0.7) mm and 10.2 (range, 8.5-12.3; SD, 0.8) mm respectively, whereas in women were 10.9 (range, 9.4-13.2; SD, 0.8) mm and 10.1 (range, 7.9-11.6; SD, 0.9) mm respectively. The difference in corresponding mean dimensions between men and women was not statistically significant. The mean AP diameter was significantly larger than the mean transverse diameter. At the base and 1.2 mm and 2.4 mm above the base, the respective transverse diameters of 4 (5%), 13 (15%), and 24 (28%) of the patients were <9.0 mm. None had an odontoid AP diameter of <9.0 mm at any level.
CONCLUSION: Two 3.5-mm cortical screws appear too big for fixation in one third of our sample presenting with type-II odontoid fracture. Fixation by two 2.7-mm screws is recommended for Malaysians and other Asian populations.

Entities:  

Mesh:

Year:  2007        PMID: 17429121     DOI: 10.1177/230949900701500115

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  6 in total

1.  Computed tomographic evaluation of odontoid process: implications for anterior screw fixation of odontoid fractures in an adult population.

Authors:  Murilo Tavares Daher; Sérgio Daher; Marcello Henrique Nogueira-Barbosa; Helton Luíz Aparecido Defino
Journal:  Eur Spine J       Date:  2011-06-21       Impact factor: 3.134

2.  Morphometric analysis of the odontoid process: using computed tomography--in the Greek population.

Authors:  D S Korres; J Lazaretos; J Papailiou; E Kyriakopoulos; D Chytas; N E Efstathopoulos; V S Nikolaou
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-11-11

3.  Computerized Tomography-Based Morphometric Analysis of Odontoid in 100 Egyptian Patients.

Authors:  Nirmal D Patil; Mohammad Essam; Raafat Kamal Ragab; Hesham Elsaghir
Journal:  Int J Spine Surg       Date:  2020-02-29

4.  CT based evaluation of odontoid morphology in the Indian population.

Authors:  Arvind G Kulkarni; Siddharth M Shah; Ruchira A Marwah; Prasad B Hanagandi; Inder R Talwar
Journal:  Indian J Orthop       Date:  2013-05       Impact factor: 1.251

5.  Morphometric parameters of the odontoid process of C2 vertebrae, in Indian population, a CT evaluation.

Authors:  Shankar Acharya; Manoj Kumar; Jay Deep Ghosh; Nitin Adsul; R S Chahal; K L Kalra
Journal:  Surg Neurol Int       Date:  2021-09-30

6.  Computed Tomographic Study of Occipital Thickness in Ethnic Malays.

Authors:  M I Yusof; A N Sadagatullah; J Johari; A A Salim; M Govindasamy
Journal:  Malays Orthop J       Date:  2022-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.