| Literature DB >> 17426815 |
Nitika Pant Pai1, Rajnish Joshi, Sandeep Dogra, Bharati Taksande, S P Kalantri, Madhukar Pai, Pratibha Narang, Jacqueline P Tulsky, Arthur L Reingold.
Abstract
BACKGROUND: Oral fluid-based rapid tests are promising for improving HIV diagnosis and screening. However, recent reports from the United States of false-positive results with the oral OraQuick ADVANCE HIV1/2 test have raised concerns about their performance in routine practice. We report a field evaluation of the diagnostic accuracy, client preference, and feasibility for the oral fluid-based OraQuick Rapid HIV1/2 test in a rural hospital in India. METHODOLOGY/PRINCIPALEntities:
Mesh:
Substances:
Year: 2007 PMID: 17426815 PMCID: PMC1838923 DOI: 10.1371/journal.pone.0000367
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1HIV Testing Algorithm
Testing algorithm and reference standard
| Scenario | OraQuick oral fluid | OraQuick finger stick | ELISA#1 | ELISA#2 | Western Blot | Tests performed | |
| 1 | NEG | NEG | then | NEG then STOP | Not done | Not done | Testing stopped with one EIA |
| 2 | NEG | NEG | then | POS | NEG | Done | All tests performed |
| 3 | POS | POS | then | POS | POS | Done | All tests performed |
| 4 | POS | NEG | then | POS | NEG | Done | All tests performed |
| 5 | NEG | POS | then | POS | POS | Done | All tests performed |
If Western Blot was indeterminate, ELISA (enzyme-linked immuno-assay) was repeated on stored sera; if repeatedly indeterminate, the sequence was repeated with a fresh blood sample
Ref: CDC guidelines for rapid testing
Diagnostic accuracy of the OraQuick HIV-1/2 rapid test performed on oral mucosal fluid specimens
| ELISA+Western Blot positive | ELISA+Western Blot negative | Total | |
| Oral fluid test positive | 146 | 0 | 146 |
| Oral fluid test negative | 0 | 304 | 304 |
| 146 | 304 | 450 |
Sensitivity = 100% (95% CI 98, 100)
Specificity = 100% (95% CI 99, 100)
Positive predictive value = 100%
Negative predictive value = 100%
Positive likelihood ratio = NA
Negative likelihood ratio = 0
Diagnostic accuracy of the OraQuick HIV-1/2 rapid test performed on finger stick blood specimens
| ELISA+Western Blot positive | ELISA+Western Blot negative | Total | |
| Finger stick test positive | 146 | 1 | 147 |
| Finger stick test negative | 0 | 303 | 304 |
| 146 | 304 | 450 |
Sensitivity = 100% (95% CI 98, 100)
Specificity = 99.7% (95% CI 98.4, 99.9)
Positive predictive value = 98.17%
Negative predictive value = 100%
Positive likelihood ratio = 304
Negative likelihood ratio = 0