Literature DB >> 17424978

Global and regional evaluation of systolic and diastolic left ventricular temporal parameters using a novel program for ECG-gated myocardial perfusion SPECT--validation by comparison with gated equilibrium radionuclide angiography and speckle-tracking radial strain from echocardiography.

Akira Yamamoto1, Naoto Takahashi, Kazuo Munakata, Tetsuo Hosoya, Masato Shiiba, Takao Okuyama, Kazuya Abe, Tadashi Kaneshiro, Haruko Tsuruta, Toshi Takama, Masashi Sato.   

Abstract

BACKGROUND: A newly developed program, named cardioGRAF, enabled the evaluation of left ventricular (LV) systolic and diastolic temporal parameters for the estimation of heart failure using ECG-gated myocardial perfusion SPECT (GMPS).
OBJECTIVE: The feasibility of those global (g-) and regional (r-) parameters was validated to compare with gated equilibrium radionuclide angiography (ERNA) and speckle-tracking radial strain (STS) from echocardiography.
METHODS: Thirty-three patients were studied using GMPS and ERNA (n=11) or GMPS and STS (n=22). The following g- or r-parameters obtained by cardioGRAF and ERNA or STS were compared: time to end systole (TES), time from end systole to peak filling rate (TPF1), time from 0 to peak filling rate (TPF2), time to peak radial strain (TPS), time from peak strain to peak negative strain rate (TP-SR1), and time from 0 to peak negative strain rate (TP-SR2).
RESULTS: All g-parameters were successfully obtained by cardioGRAF and ERNA. The results demonstrated good correlations (g-TES: r = 0.79, p < 0.005; g-TPF1: r = 0.75, p < 0.02; TPF2: r = 0.83, p < 0.005). The differences were 11.9 +/- 31.8 ms in g-TES, 19.9 +/- 65.4 ms in g-TPF1, and 37.7 +/- 67.4 ms in g-TPF2. All r-parameters were successfully obtained by cardioGRAF. Eight patients and 12 segments were excluded because of the inadequate quality of routine echocardiography for STS analysis. However, r-parameters obtained by cardioGRAF were significantly correlated with those of STS (r-TES and r-TPS: r = 0.61, p = 1 x 10(-8); r-TPF1 and r-TP-SR1: r = 0.69, p = 3 x 10(-11); r-TPF2 and r-TP-SR2: r = 0.76, p = 2 x 10(-15)). The differences were 22.1 +/- 38.2 ms between r-TES and r-TPS, 7.0 +/- 123.4 ms between r-TPF1 and r-TP-SR1, and 38.1 +/- 111.5 ms between r-TPF2 and r-TP-SR2.
CONCLUSION: The feasibility of evaluating systolic and diastolic temporal parameters by a new program was validated. This program has the potential to evaluate both diastolic and systolic heterogeneous wall motions which express dyssynchrony in heart failure.

Entities:  

Mesh:

Year:  2007        PMID: 17424978     DOI: 10.1007/bf03033989

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  3 in total

1.  Regional left-ventricular diastolic wall motion assessed by a new program for ECG-gated myocardial perfusion SPECT in early-stage heart failure.

Authors:  Akira Yamamoto; Naoto Takahashi; Kazuya Abe; Yuko Kobayashi; Jin Tamai; Kazuo Munakata
Journal:  J Nucl Cardiol       Date:  2008-04-16       Impact factor: 5.952

2.  Demonstration of left ventricular dyssynchrony and resynchrony by ECG-gated SPECT with cardioGRAF in a patient with advanced heart failure and narrow QRS complex.

Authors:  Itsuro Morishima; Takahito Sone; Hideyuki Tsuboi; Hiroaki Mukawa; Michitaka Uesugi; Kazunori Hayashi
Journal:  J Interv Card Electrophysiol       Date:  2009-01-16       Impact factor: 1.900

3.  Left ventricular dyssynchrony in patients with moderate coronary stenosis and border line fractional flow reserve.

Authors:  Yohei Shibata; Takahito Sone; Hideyuki Tsuboi; Satoshi Isobe; Hideki Ishii; Susumu Suzuki; Mutsuharu Hayashi; Toyoaki Murohara
Journal:  Nagoya J Med Sci       Date:  2015-02       Impact factor: 1.131

  3 in total