Literature DB >> 17418334

Arthroscopic treatment of nonunited anterior cruciate ligament tibial avulsion fracture with figure-of-8 suture fixation technique.

Jinzhong Zhao1, Xiaoqiao Huangfu.   

Abstract

PURPOSE: The purpose of this study was to evaluate the clinical results of arthroscopic treatment of nonunited anterior cruciate ligament (ACL) tibial avulsion fracture with a figure-of-8 suture fixation technique.
METHODS: Nineteen cases of nonunited ACL tibial avulsion fracture were treated with an arthroscopic figure-of-8 suture fixation technique. The patients were followed up and evaluated according to the International Knee Documentation Committee, Lysholm, and Tegner rating scales.
RESULTS: The time interval between the previous injury and this operation was 1 to 8 years, with a mean of 3.6 years. Eighteen patients were followed up for more than 2 years (range, 24 to 30 months; mean, 26 months). The fracture was united within 3 months after surgery in all cases. At the latest follow-up, there was neither extension nor flexion limitation in all patients. With the exception of 1 patient who had a 1 degrees positive Lachman test with a firm end-point, all of the patients had a negative Lachman test. The side-to-side difference in knee anterior laxity was 0 to 2 mm in 17 patients and 4 mm in 1 patient. The Lysholm score was 91 to 100, with a mean of 96.7 +/- 1.9 (compared with 74.3 +/- 4.6 before surgery, P < .05). Fifteen patients returned to their former activity level. The Tegner scores before injury, preoperatively, and at latest follow-up were 6.1 +/- 0.6, 3.6 +/- 1.0, and 6.0 +/- 0.8, respectively; there was no statistically significant difference between the preinjury and postoperative Tegner scores (P > .05). According to the International Knee Documentation Committee scale, 17 patients' knees were graded as normal and 1 patient's knee was nearly normal.
CONCLUSIONS: Arthroscopic treatment of nonunited ACL tibial avulsion fracture with a figure-of-8 suture fixation technique can ensure fracture healing and restore the stability and function of the joint in most patients. LEVEL OF EVIDENCE: Level IV, therapeutic case series.

Entities:  

Mesh:

Year:  2007        PMID: 17418334     DOI: 10.1016/j.arthro.2006.12.008

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  11 in total

1.  A comparative study of two methods for treating type III tibial eminence avulsion fracture in adults.

Authors:  Weilin Sang; Libo Zhu; Jinzhong Ma; Haiming Lu; Yinxian Yu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-10       Impact factor: 4.342

2.  Biomechanical comparison of three techniques for fixation of tibial avulsion fractures of the anterior cruciate ligament.

Authors:  Yong In; Dai-Soon Kwak; Chan-Woong Moon; Seung-Ho Han; Nam-Yong Choi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-11       Impact factor: 4.342

3.  Bioabsorbable sutures versus screw fixation of displaced tibial eminence fractures: a biomechanical study.

Authors:  Vladimir Senekovic; Matej Balazic
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-02-09

4.  Reduction and fixation of the avulsion fracture of the tibial eminence using mini-open technique.

Authors:  Xiong-Wei Lu; Xiao-Peng Hu; Chen Jin; Tong Zhu; Yong Ding; Li-Yang Dai
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-02-03       Impact factor: 4.342

5.  Treatment of tibial eminence fractures with arthroscopic suture fixation technique: a retrospective study.

Authors:  Yanhao Yuan; Xiaohan Huang; Yanjie Zhang; Zhanchao Wang
Journal:  Int J Clin Exp Med       Date:  2015-08-15

6.  Arthroscopic treatment of displaced tibial eminence fractures using a suspensory fixation.

Authors:  Philippe Loriaut; Pierre-Emmanuel Moreau; Patrick Loriaut; Patrick Boyer
Journal:  Indian J Orthop       Date:  2017 Mar-Apr       Impact factor: 1.251

7.  "Figure-of-Eight" Suture-Button Technique for Fixation of Displaced Anterior Cruciate Ligament Avulsion Fracture.

Authors:  Shi-da Kuang; Chao Su; Xin Zhao; Yu-Sheng Li; Yi-Lin Xiong; Shu-Guang Gao
Journal:  Orthop Surg       Date:  2020-04-29       Impact factor: 2.071

8.  Pediatric Type II Tibial Spine Fractures: Addressing the Treatment Controversy With a Mixed-Effects Model.

Authors:  Alexander J Adams; Nathan N O'Hara; Joshua M Abzug; Julien T Aoyama; Theodore J Ganley; James L Carey; Aristides I Cruz; Henry B Ellis; Peter D Fabricant; Daniel W Green; Benton E Heyworth; Joseph A Janicki; Mininder S Kocher; John T R Lawrence; R Jay Lee; Scott D McKay; R Justin Mistovich; Neeraj M Patel; John D Polousky; Jason T Rhodes; Brant C Sachleben; M Catherine Sargent; Gregory A Schmale; Kevin G Shea; Yi-Meng Yen
Journal:  Orthop J Sports Med       Date:  2019-08-28

9.  Pediatric tibial eminence fracture treatment: A case series using a bioabsorbable screw.

Authors:  M Wesley Honeycutt; Anna J Rambo; Daniel P Zieman; Prasit Nimityongskul
Journal:  J Clin Orthop Trauma       Date:  2020-02-01

10.  Arthroscopic Suture-to-Adjustable Loop Fixation of Adult Anterior Cruciate Ligament Tibial Avulsion Fracture.

Authors:  Jin Tang; Jinzhong Zhao
Journal:  Arthrosc Tech       Date:  2021-05-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.