Xiaoqin Li1, Taoguang Huo, Feng Qin, Xiumei Lu, Famei Li.
Abstract
A high-performance liquid chromatography (HPLC) method was developed and validated for the determination of orientin in rabbit plasma using ultraviolet (UV) absorbance detection. Orientin is the active constituent of purified herbal extract (TRO PE) from the flower of Trollius chinensis Bunge. Protein precipitation was used as the sample preparation technique. A Diamonsil C18 column (150 mmx4.6 mm, 5 microm) was equilibrated with a mobile phase composed of 0.1% acetic acid/methanol/acetonitrile (80/5/15, v/v/v). The calibration curve of orientin in rabbit plasma was linear in the concentration range of 0.530-53.0 microg/mL. This validated method was successfully applied to a pharmacokinetic study in rabbits after the intravenous administrations of orientin and TRO PE at three different doses.Entities:
Mesh:
Substances:
Year: 2007 PMID: 17416555 DOI: 10.1016/j.jchromb.2007.03.020
Source DB: PubMed Journal: J Chromatogr B Analyt Technol Biomed Life Sci ISSN: 1570-0232 Impact factor: 3.205