Literature DB >> 17414966

Development of volume conductor and source models to localize epileptic foci.

Manfred Fuchs1, Michael Wagner, Joern Kastner.   

Abstract

SUMMARY: There is increasing interest in mapping and source reconstruction from electrocorticoencephalographic (ECoG) grid data and comparison to surface EEG evaluations of epileptic patients. ECoG mapping onto three-dimensional renderings of the individual cortical anatomy derived from magnetic resonance images and computed tomography (CT) is performed after coregistration of anatomical and functional coordinate systems. Source reconstructions from ECoG and EEG are compared using different source models and realistically shaped volume conductor models. Realistically shaped volume conductor models for EEG source reconstruction are a prerequisite for improved localization accuracy. Individual boundary element method (BEM) models derived from MRI represent the "gold standard" and can approximate isotropic homogeneous head compartments and thus give an improved description of the head shape as compared with classical oversimplifying spherical shell models. Anisotropic volume conduction properties of the bone layer or the white matter fibers can be described by the finite element method (FEM); unfortunately, these models require a huge computational effort and are thus not used in daily applications. To avoid this computational effort, head models derived from an averaged MRI dataset can be used. Highly refined models with a large number of nodes and thus better numerical accuracy can be used by this approach, because the setup is performed only once and the decomposed models or precomputed leadfield matrices are saved for later application. Individual image data are not at all needed, if an overlay of the reconstruction results with the anatomy is not desired. With precomputed leadfield matrices and linear interpolation techniques, at least standardized BEM and FEM volume conductor models derived from averaged MRI datasets can achieve the same computational speed as analytical spherical models. The smoothed cortical envelope is used as a realistically shaped single-shell volume conductor model for ECoG source reconstruction, whereas three-compartment BEM-models are required for EEG. The authors describe how to localize ECoG-grid electrode positions and how to segment the cortical surface from coregistered magnetic resonance and CT images. Landmark-based coregistration is performed using common fiducials in both image modalities. Another more promising automatic approach is based on mutual three-dimensional volume gray-level information. The ECoG electrode positions can be retrieved from three-dimensional CT slices manually using cursors in thresholded images with depth information. Alternatively, the smoothed envelope of the cortical surface segmented from the MRI is used to semiautomatically determine the grid electrode positions by marking the four corners and measuring distances along the smoothed surface. With extended source patches for cortically constrained scans and current density reconstructions, results from ECoG and surface EEG data were compared. Single equivalent dipoles were used to explain the EEG far fields, and results were compared with the original current density distributions explaining the ECoG data. The authors studied the performance of spherical and realistically shaped BEM volume conductor models for EEG and ECoG source reconstruction in spherical and nonspherical parts of the head with simulations and measured epileptic spike data. Only small differences between spherical and realistically shaped models were found in the spherical parts of the head, whereas realistically shaped models are superior to spherical approximations in both single-shell ECoG and three-shell EEG cases in the nonspherical parts, such as the temporal lobe areas. The ECoG near field is more complicated to interpret than the surface EEG far field and cannot be explained in general by simple equivalent dipoles. However, from simulations with realistically shaped volume conductor models and cortically constrained source models, the authors studied how the bone and skin layer act as spatial low pass filters that smooth and simplify the surface EEG maps generated by much more complicated-looking source configurations derived from measured ECoG data.

Entities:  

Mesh:

Year:  2007        PMID: 17414966     DOI: 10.1097/WNP.0b013e318038fb3e

Source DB:  PubMed          Journal:  J Clin Neurophysiol        ISSN: 0736-0258            Impact factor:   2.177


  29 in total

1.  Mapping repetition suppression of the N100 evoked response to the human cerebral cortex.

Authors:  Nash N Boutros; Klevest Gjini; Horst Urbach; Mark E Pflieger
Journal:  Biol Psychiatry       Date:  2011-01-28       Impact factor: 13.382

2.  Modeling of the human skull in EEG source analysis.

Authors:  Moritz Dannhauer; Benjamin Lanfer; Carsten H Wolters; Thomas R Knösche
Journal:  Hum Brain Mapp       Date:  2010-08-05       Impact factor: 5.038

3.  Sensitivity of beamformer source analysis to deficiencies in forward modeling.

Authors:  Olaf Steinsträter; Stephanie Sillekens; Markus Junghoefer; Martin Burger; Carsten H Wolters
Journal:  Hum Brain Mapp       Date:  2010-05-24       Impact factor: 5.038

4.  Intracranial recording and source localization of auditory brain responses elicited at the 50 ms latency in three children aged from 3 to 16 years.

Authors:  Oleg Korzyukov; Eishi Asano; Valentina Gumenyuk; Csaba Juhász; Michael Wagner; Robert D Rothermel; Harry T Chugani
Journal:  Brain Topogr       Date:  2009-08-22       Impact factor: 3.020

5.  sLORETA allows reliable distributed source reconstruction based on subdural strip and grid recordings.

Authors:  Matthias Dümpelmann; Tonio Ball; Andreas Schulze-Bonhage
Journal:  Hum Brain Mapp       Date:  2011-05-26       Impact factor: 5.038

6.  Mapping repetition suppression of the P50 evoked response to the human cerebral cortex.

Authors:  Nash N Boutros; Klevest Gjini; Simon B Eickhoff; Horst Urbach; Mark E Pflieger
Journal:  Clin Neurophysiol       Date:  2012-11-04       Impact factor: 3.708

Review 7.  Noninvasive imaging of cardiac excitation: current status and future perspective.

Authors:  A W Maurits van der Graaf; Pranav Bhagirath; Hemanth Ramanna; Vincent J H M van Driel; Jacques de Hooge; Natasja M S de Groot; Marco J W Götte
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-02-19       Impact factor: 1.468

8.  Three-dimensional visualization of subdural electrodes for presurgical planning.

Authors:  Peter S LaViolette; Scott D Rand; Manoj Raghavan; Benjamin M Ellingson; Kathleen M Schmainda; Wade Mueller
Journal:  Neurosurgery       Date:  2011-03       Impact factor: 4.654

9.  Realistic and spherical head modeling for EEG forward problem solution: a comparative cortex-based analysis.

Authors:  Federica Vatta; Fabio Meneghini; Fabrizio Esposito; Stefano Mininel; Francesco Di Salle
Journal:  Comput Intell Neurosci       Date:  2010-02-14

10.  Differential maturation of brain signal complexity in the human auditory and visual system.

Authors:  Sarah Lippé; Natasa Kovacevic; Anthony Randal McIntosh
Journal:  Front Hum Neurosci       Date:  2009-11-16       Impact factor: 3.169

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.