Literature DB >> 17414811

Influence of speed and step frequency during walking and running on motion sensor output.

Ann V Rowlands1, Michelle R Stone, Roger G Eston.   

Abstract

PURPOSE: Studies have reported strong linear relationships between accelerometer output and walking/running speeds up to 10 km x h(-1). However, ActiGraph uniaxial accelerometer counts plateau at higher speeds. The aim of this study was to determine the relationships of triaxial accelerometry, uniaxial accelerometry, and pedometry with speed and step frequency (SF) across a range of walking and running speeds.
METHODS: Nine male runners wore two ActiGraph uniaxial accelerometers, two RT3 triaxial accelerometers (all set at a 1-s epoch), and two Yamax pedometers. Each participant walked for 60 s at 4 and 6 km x h(-1), ran for 60 s at 10, 12, 14, 16, and 18 km x h(-1), and ran for 30 s at 20, 22, 24, and 26 km x h(-1). Step frequency was recorded by a visual count.
RESULTS: ActiGraph counts peaked at 10 km x h(-10 (2.5-3.0 Hz SF) and declined thereafter (r=0.02, P>0.05). After correction for frequency-dependent filtering, output plateaued at 10 km x h(-1) but did not decline (r=0.77, P<0.05). Similarly, RT3 vertical counts plateaued at speeds > 10 km x h(-1) (r=0.86, P<0.01). RT3 vector magnitude and anteroposterior and mediolateral counts maintained a linear relationship with speed (r>0.96, P<0.001). Step frequency assessed by pedometry compared well with actual step frequency up to 20 km x h(-1) (approximately 3.5 Hz) but then underestimated actual steps (Yamax r=0.97; ActiGraph pedometer r=0.88, both P<0.001).
CONCLUSION: Increasing underestimation of activity by the ActiGraph as speed increases is related to frequency-dependent filtering and assessment of acceleration in the vertical plane only. RT3 vector magnitude was strongly related to speed, reflecting the predominance of horizontal acceleration at higher speeds. These results indicate that high-intensity activity is underestimated by the ActiGraph, even after correction for frequency-dependent filtering, but not by the RT3. Pedometer output is highly correlated with step frequency.

Entities:  

Mesh:

Year:  2007        PMID: 17414811     DOI: 10.1249/mss.0b013e318031126c

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  31 in total

1.  Pedometer accuracy during stair climbing and bench stepping exercises.

Authors:  Makoto Ayabe; Junichiro Aoki; Kojiro Ishii; Kohsaku Takayama; Hiroaki Tanaka
Journal:  J Sports Sci Med       Date:  2008-06-01       Impact factor: 2.988

2.  The validity of two Omron pedometers during treadmill walking is speed dependent.

Authors:  Dimitra M Giannakidou; Antonis Kambas; Nikolaos Ageloussis; Ioannis Fatouros; Christos Christoforidis; Fotini Venetsanou; Ioannis Douroudos; Kyriakos Taxildaris
Journal:  Eur J Appl Physiol       Date:  2011-04-09       Impact factor: 3.078

Review 3.  Walking and running on treadmill: the standard criteria for kinematics studies.

Authors:  Johnny Padulo; Karim Chamari; Luca Paolo Ardigò
Journal:  Muscles Ligaments Tendons J       Date:  2014-07-14

Review 4.  How consumer physical activity monitors could transform human physiology research.

Authors:  Stephen P Wright; Tyish S Hall Brown; Scott R Collier; Kathryn Sandberg
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2017-01-04       Impact factor: 3.619

5.  Biomechanical examination of the 'plateau phenomenon' in ActiGraph vertical activity counts.

Authors:  Dinesh John; Ross Miller; Sarah Kozey-Keadle; Graham Caldwell; Patty Freedson
Journal:  Physiol Meas       Date:  2012-01-20       Impact factor: 2.833

Review 6.  Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review.

Authors:  Valentina Camomilla; Elena Bergamini; Silvia Fantozzi; Giuseppe Vannozzi
Journal:  Sensors (Basel)       Date:  2018-03-15       Impact factor: 3.576

7.  Wireless sensors for continuous, multimodal measurements at the skin interface with lower limb prostheses.

Authors:  Jean Won Kwak; Mengdi Han; Zhaoqian Xie; Ha Uk Chung; Jong Yoon Lee; Raudel Avila; Jessica Yohay; Xuexian Chen; Cunman Liang; Manish Patel; Inhwa Jung; Jongwon Kim; Myeong Namkoong; Kyeongha Kwon; Xu Guo; Christopher Ogle; Dominic Grande; Dennis Ryu; Dong Hyun Kim; Surabhi Madhvapathy; Claire Liu; Da Som Yang; Yoonseok Park; Ryan Caldwell; Anthony Banks; Shuai Xu; Yonggang Huang; Stefania Fatone; John A Rogers
Journal:  Sci Transl Med       Date:  2020-12-16       Impact factor: 17.956

8.  Testing the 'teachable moment' premise: does physical activity increase in the early survivorship phase?

Authors:  J M Broderick; J Hussey; M J Kennedy; D M O'Donnell
Journal:  Support Care Cancer       Date:  2013-11-27       Impact factor: 3.603

9.  Comparison of four ActiGraph accelerometers during walking and running.

Authors:  Dinesh John; Brian Tyo; David R Bassett
Journal:  Med Sci Sports Exerc       Date:  2010-02       Impact factor: 5.411

10.  Patient activity after TKA depends on patient-specific parameters.

Authors:  Cornelia Lützner; Stephan Kirschner; Jörg Lützner
Journal:  Clin Orthop Relat Res       Date:  2014-07-23       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.