Comparison of 2 different protocols for ingestion of low-attenuating oral contrast agent for multidetector computed tomography of the abdomen.

Thomas M Meindl1, Elfriede Hagl, Maximilian F Reiser, Ullrich G Mueller-Lisse.   

Abstract

OBJECTIVE: To evaluate 2 different oral contrast application protocols concerning degree of intestinal contrast filling and distension in multidetector computed tomography.
METHODS: Examinations of 260 patients were retrospectively analyzed. Group 1 (n = 205) was prepared with 1000 mL of water with 28 g of dissolved mannitol which was ingested for 1 hour; group 2 (n = 55) was prepared with 2000 mL of water containing 56 g of mannitol which was ingested for 2 hours. Small intestine was divided into 4 quadrants; colon was divided into 4 segments. Contrast filling and distension of bowel loops were graded with a 3-point scale and compared using chi2 testing.
RESULTS: Besides the right upper quadrant, no significant differences in contrast filling and distention were found for small bowel segments. Colonic segments were significantly better contrast filled and distended in group 2 (0.001 < P < 0.025).
CONCLUSIONS: A higher amount of water with 28 g/L of mannitol and a prolonged ingestion of oral contrast media result in significantly better contrast filling and bowel distension in the ileocecal region, the colon, and the rectum.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17414757     DOI: 10.1097/01.rct.0000237813.26301.73

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  3 in total

1.  Improvement of distension and mural visualization of bowel loops using neutral oral contrasts in abdominal computed tomography.

Authors:  Jahanbakhsh Hashemi; Yasmin Davoudi; Mina Taghavi; Masoud Pezeshki Rad; Amien Mahajeri Moghadam
Journal:  World J Radiol       Date:  2014-12-28

2.  Comparison of Mannitol, Water, and Iodine-Based Oral Contrast in the Evaluation of the Bowel by Multi-Detector Computed Tomography.

Authors:  Sai Soumya Thati; Rachegowda Nagegowda; Anil K Sakalecha; Shivaprasad G Savagave; Divya T Patil
Journal:  Cureus       Date:  2022-04-20

3.  Quantitative and qualitative bowel analysis using mannitol, water and iodine-based endoluminal contrast agent on 64-row detector CT.

Authors:  K Prakashini; Chandan Kakkar; Charudutt Sambhaji; Chandrakant M Shetty; Vedula Rajanikanth Rao
Journal:  Indian J Radiol Imaging       Date:  2013-10
  3 in total