OBJECTIVES: To investigate interobserver variability in the delineation of head-and-neck (H&N) anatomic structures on CT images, including the effects of image artifacts and observer experience. METHODS: Nine observers (7 radiation oncologists, 1 surgeon, and 1 physician assistant) with varying levels of H&N delineation experience independently contoured H&N gross tumor volumes and critical structures on radiation therapy treatment planning CT images alongside reference diagnostic CT images for 4 patients with oropharynx cancer. Image artifacts from dental fillings partially obstructed 3 images. Differences in the structure volumes, center-of-volume positions, and boundary positions (1 SD) were measured. In-house software created three-dimensional overlap distributions, including all observers. The effects of dental artifacts and observer experience on contouring precision were investigated, and the need for contrast media was assessed. RESULTS: In the absence of artifacts, all 9 participants achieved reasonable precision (1 SD < or =3 mm all boundaries). The structures obscured by dental image artifacts had larger variations when measured by the 3 metrics (1 SD = 8 mm cranial/caudal boundary). Experience improved the interobserver consistency of contouring for structures obscured by artifacts (1 SD = 2 mm cranial/caudal boundary). CONCLUSIONS: Interobserver contouring variability for anatomic H&N structures, specifically oropharyngeal gross tumor volumes and parotid glands, was acceptable in the absence of artifacts. Dental artifacts increased the contouring variability, but experienced participants achieved reasonable precision even with artifacts present. With a staging contrast CT image as a reference, delineation on a noncontrast treatment planning CT image can achieve acceptable precision.
OBJECTIVES: To investigate interobserver variability in the delineation of head-and-neck (H&N) anatomic structures on CT images, including the effects of image artifacts and observer experience. METHODS: Nine observers (7 radiation oncologists, 1 surgeon, and 1 physician assistant) with varying levels of H&N delineation experience independently contoured H&N gross tumor volumes and critical structures on radiation therapy treatment planning CT images alongside reference diagnostic CT images for 4 patients with oropharynx cancer. Image artifacts from dental fillings partially obstructed 3 images. Differences in the structure volumes, center-of-volume positions, and boundary positions (1 SD) were measured. In-house software created three-dimensional overlap distributions, including all observers. The effects of dental artifacts and observer experience on contouring precision were investigated, and the need for contrast media was assessed. RESULTS: In the absence of artifacts, all 9 participants achieved reasonable precision (1 SD < or =3 mm all boundaries). The structures obscured by dental image artifacts had larger variations when measured by the 3 metrics (1 SD = 8 mm cranial/caudal boundary). Experience improved the interobserver consistency of contouring for structures obscured by artifacts (1 SD = 2 mm cranial/caudal boundary). CONCLUSIONS: Interobserver contouring variability for anatomic H&N structures, specifically oropharyngeal gross tumor volumes and parotid glands, was acceptable in the absence of artifacts. Dental artifacts increased the contouring variability, but experienced participants achieved reasonable precision even with artifacts present. With a staging contrast CT image as a reference, delineation on a noncontrast treatment planning CT image can achieve acceptable precision.
Authors: Carryn M Anderson; Wenqing Sun; John M Buatti; Joan E Maley; Bruno Policeni; Sarah L Mott; John E Bayouth Journal: Jacobs J Radiat Oncol Date: 2014-09
Authors: Asma Amjad; Jiaofeng Xu; Dan Thill; Colleen Lawton; William Hall; Musaddiq J Awan; Monica Shukla; Beth A Erickson; X Allen Li Journal: Med Phys Date: 2022-02-07 Impact factor: 4.071
Authors: Holly M Parenica Paschal; Christopher N Kabat; Pavlos Papaconstadopoulos; Neil A Kirby; Pamela A Myers; Timothy D Wagner; Sotirios Stathakis Journal: J Appl Clin Med Phys Date: 2022-08-19 Impact factor: 2.243
Authors: David Thomson; Chris Boylan; Tom Liptrot; Adam Aitkenhead; Lip Lee; Beng Yap; Andrew Sykes; Carl Rowbottom; Nicholas Slevin Journal: Radiat Oncol Date: 2014-08-03 Impact factor: 3.481
Authors: Sweet Ping Ng; Brandon A Dyer; Jayashree Kalpathy-Cramer; Abdallah Sherif Radwan Mohamed; Musaddiq J Awan; G Brandon Gunn; Jack Phan; Mark Zafereo; J Matthew Debnam; Carol M Lewis; Rivka R Colen; Michael E Kupferman; Nandita Guha-Thakurta; Guadalupe Canahuate; G Elisabeta Marai; David Vock; Bronwyn Hamilton; John Holland; Carlos E Cardenas; Stephen Lai; David Rosenthal; Clifton David Fuller Journal: Clin Transl Radiat Oncol Date: 2018-08-02