Long-term results of one-level lumbar arthroplasty: minimum 10-year follow-up of the CHARITE artificial disc in 106 patients.

Thierry David1.   

Abstract

STUDY
DESIGN: A retrospective chart and radiographic review.
OBJECTIVES: To determine the long-term clinical results, radiographic results, and incidence of complications in a large patient cohort with one-level lumbar total disc replacement (TDR). SUMMARY OF BACKGROUND DATA: Prior authors have described short-term, mid-term, and long-term clinical and radiographic results in patients with lumbar TDR with highly variable results.
METHODS: From January 1989 to November 1995, 108 patients, with a mean age of 36.4 years, underwent lumbar TDR with the CHARITE Artificial Disc, with 106 available for follow-up. A modified Stauffer-Coventry scale was used to determine clinical outcome. Return to work, work level, and the incidence of complications were assessed. Dynamic lateral flexion-extension and lateral bending radiographs were performed and segmental range of motion (ROM) was measured using the Cobb method.
RESULTS: Mean follow-up time was 13.2 years (range, 10-16.8 years). Of the 106 patients, 87 (82.1%) had either an excellent or good clinical outcome. Of the 96 patients working before surgery, 86 returned to work (89.6%), including 77.8% of patients with hard labor level employment (28 of 36) returning to the same level of work. The mean ROM in flexion-extension was 10.1 degrees , in lateral bending it was 4.4 degrees , and 90.6% of implanted prostheses were still mobile. Eight patients (7.5%) required posterior instrumented fusion. There were 5 cases (4.6%) of postoperative facet arthrosis, 3 cases (2.8%) of subsidence, 3 cases (2.8%) of adjacent-level disease, and 2 cases (1.9%) of core subluxation.
CONCLUSIONS: This retrospective study demonstrates the safety and efficacy of the CHARITE Artificial Disc at one level, either L4-L5 or L5-S1, in the long-term. Clinical outcomes and the rate of return to work were excellent overall. The rate of adjacent-level disease requiring surgical intervention was considerably lower (2.8%) compared with reports in the literature for lumbar fusion. As with any surgical procedure, proper indications play a pivotal role in clinical success.

Entities:  

Mesh:

Year:  2007        PMID: 17413471     DOI: 10.1097/01.brs.0000257554.67505.45

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  56 in total

1.  Analysis of biomechanical changes after removal of instrumentation in lumbar arthrodesis by finite element analysis.

Authors:  Ho-Joong Kim; Heoung-Jae Chun; Seong-Hwan Moon; Kyoung-Tak Kang; Hak-Sun Kim; Jin-Oh Park; Eun-Su Moon; Joon-Seok Sohn; Hwan-Mo Lee
Journal:  Med Biol Eng Comput       Date:  2010-05-04       Impact factor: 2.602

2.  The impact of implantation technique on frontal and sagittal alignment in total lumbar disc replacement: a comparison of anterior versus oblique implantation.

Authors:  René Schmidt; U Obertacke; J Nothwang; C Ulrich; J Nowicki; H Reichel; B Cakir
Journal:  Eur Spine J       Date:  2010-05-21       Impact factor: 3.134

3.  Effects of lumbar artificial disc design on intervertebral mobility: in vivo comparison between mobile-core and fixed-core.

Authors:  Joël Delécrin; Jérôme Allain; Jacques Beaurain; Jean-Paul Steib; Jean Huppert; Hervé Chataigner; Marc Ameil; Lucie Aubourg; Jean-Michel Nguyen
Journal:  Eur Spine J       Date:  2010-12-11       Impact factor: 3.134

4.  Influence of lumbar intervertebral disc degeneration on the outcome of total lumbar disc replacement: a prospective clinical, histological, X-ray and MRI investigation.

Authors:  Christoph J Siepe; Franziska Heider; Elisabeth Haas; Wolfgang Hitzl; Ulrike Szeimies; Axel Stäbler; Christoph Weiler; Andreas G Nerlich; Michael H Mayer
Journal:  Eur Spine J       Date:  2012-05-29       Impact factor: 3.134

5.  Prospective clinical and radiographic results of CHARITÉ III artificial total disc arthroplasty at 2- to 7-year follow-up: a Canadian experience.

Authors:  Michael Katsimihas; Christopher S Bailey; Khalil Issa; Jennifer Fleming; Patricia Rosas-Arellano; Stewart I Bailey; Kevin R Gurr
Journal:  Can J Surg       Date:  2010-12       Impact factor: 2.089

Review 6.  [Revision surgery after implantation of a vertebral disc prosthesis].

Authors:  C Hopf
Journal:  Orthopade       Date:  2008-04       Impact factor: 1.087

Review 7.  [Lumbar total disc replacement].

Authors:  D Grob
Journal:  Orthopade       Date:  2009-01       Impact factor: 1.087

8.  Clinical evaluation of a lumbar interspinous dynamic stabilization device (the Wallis system) with a 13-year mean follow-up.

Authors:  Jacques Sénégas; Jean-Marc Vital; Vincent Pointillart; Paolo Mangione
Journal:  Neurosurg Rev       Date:  2009-04-22       Impact factor: 3.042

Review 9.  [Adjacent segment movement after monosegmental total disc replacement and monosegmental fusion of segments L4/5].

Authors:  M Däxle; T Kocak; F Lattig; H Reichel; B Cakir
Journal:  Orthopade       Date:  2013-02       Impact factor: 1.087

10.  [Current short- and long-term results of lumbar disc replacement : update 2008].

Authors:  B Wiedenhöfer; V Ewerbeck; A J Suda; C Carstens
Journal:  Chirurg       Date:  2008-10       Impact factor: 0.955

View more