Literature DB >> 17412544

Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: comparison with digital subtraction angiography.

Fabio Pozzi-Mucelli1, Stefano Bruni, Marco Doddi, Antonio Calgaro, Massimiliano Braini, Maria Cova.   

Abstract

PURPOSE: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. METHODS AND MATERIALS: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference.
RESULTS: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%.
CONCLUSIONS: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect.

Entities:  

Mesh:

Year:  2007        PMID: 17412544     DOI: 10.1016/j.ejrad.2007.02.018

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  10 in total

1.  Cerebral CT angiography using a small volume of concentrated contrast material with a test injection method: optimal scan delay for quantitative and qualitative performance.

Authors:  N Takeyama; K Kuroki; T Hayashi; S Sai; N Okabe; Y Kinebuchi; T Hashimoto; T Gokan
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

Review 2.  Multislice computed tomography angiography in the diagnosis of cardiovascular disease: 3D visualizations.

Authors:  Zhonghua Sun
Journal:  Front Med       Date:  2011-10-02       Impact factor: 4.592

3.  Optimal scan timing for artery-vein separation at whole-brain CT angiography using a 320-row MDCT volume scanner.

Authors:  Takashi Shirasaka; Akio Hiwatashi; Koji Yamashita; Masatoshi Kondo; Hiroshi Hamasaki; Yamato Shimomiya; Yasuhiko Nakamura; Yoshinori Funama; Hiroshi Honda
Journal:  Br J Radiol       Date:  2016-12-20       Impact factor: 3.039

4.  Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography.

Authors:  Qi Li; Fajin Lv; Yongmei Li; Kewei Li; Tianyou Luo; Peng Xie
Journal:  Eur Radiol       Date:  2009-05-01       Impact factor: 5.315

5.  Detection of aneurysms by 64-section multidetector CT angiography in patients acutely suspected of having an intracranial aneurysm and comparison with digital subtraction and 3D rotational angiography.

Authors:  A M McKinney; C S Palmer; C L Truwit; A Karagulle; M Teksam
Journal:  AJNR Am J Neuroradiol       Date:  2007-12-07       Impact factor: 3.825

6.  Diagnostic Impact of Bone-Subtraction CT Angiography for Patients with Acute Subarachnoid Hemorrhage.

Authors:  P Aulbach; D Mucha; K Engellandt; K Hädrich; M Kuhn; R von Kummer
Journal:  AJNR Am J Neuroradiol       Date:  2015-10-08       Impact factor: 3.825

7.  Dual-energy direct bone removal CT angiography for evaluation of intracranial aneurysm or stenosis: comparison with conventional digital subtraction angiography.

Authors:  Yoshiyuki Watanabe; Kensuke Uotani; Tetsuro Nakazawa; Masahiro Higashi; Naoaki Yamada; Yoshiro Hori; Suzu Kanzaki; Tetsuya Fukuda; Toshihide Itoh; Hiroaki Naito
Journal:  Eur Radiol       Date:  2008-11-11       Impact factor: 5.315

8.  The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage.

Authors:  Masih Saboori; Ali Hekmatnia; Amirhossein Ghazavi; Reza Basiratnia; Navid Omidifar; Farzaneh Hekmatnia; Homayoon Naji Isfahani
Journal:  J Res Med Sci       Date:  2011-08       Impact factor: 1.852

9.  The Role of 3 Tesla MRA in the Detection of Intracranial Aneurysms.

Authors:  Eftychia Z Kapsalaki; Christos D Rountas; Kostas N Fountas
Journal:  Int J Vasc Med       Date:  2012-01-16

10.  The Impact of Transient Hepatic Attenuation Differences in the Diagnosis of Pseudoaneurysm and Arteriovenous Fistula on Follow-Up CT Scans after Blunt Liver Trauma.

Authors:  Andreas Hjelm Brandt; Caroline Ewertsen; Kristoffer Lindskov Hansen
Journal:  Diagnostics (Basel)       Date:  2014-09-10
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.