Literature DB >> 17412349

The effect of recovery time and test conditions on viscoelastic measures of tensile damage in cortical bone.

Won Joo1, Karl J Jepsen, Dwight T Davy.   

Abstract

Stiffness degradation and strength degradation are often measured to monitor and characterize the effects of damage accumulation in bone. Based on evidence that these properties could be affected by not only damage magnitude but also test conditions, the present study investigated the effect of hold condition and recovery time on measures of tensile damage. Machined human femoral cortical bone specimens were subjected to tensile tests consisting of a pre-damage diagnostic loading cycle, a damage loading cycle and post-damage cycle. Controlled variables were recovery time (1, 10, and 100 min) and hold condition (zero load or zero strain) after the damage cycle. Damage measures were calculated as the ratio of each post-damage cycle to the pre-damage value for loading modulus, secant modulus, unloading modulus, stress relaxation and strain (stress) recovery at 1 min post-diagnostic time. The damage cycle caused reductions in all measures, and some measures varied with recovery time and hold condition. Apparent modulus degradation for both hold conditions decreased with recovery time. Stress relaxation was unaffected by recovery time for both hold conditions. Zero-strain hold conditions resulted in lower values for degradation of modulus and change of relaxation. Stress or strain recovery after the damage cycle was evident through 100 min, but 90% of the recovery occurred within 10 min. The results demonstrate that choice of test conditions can influence the apparent magnitude of damage effects. They also indicate that 10 min recovery time was sufficient to stabilize most measures of the damage state.

Entities:  

Mesh:

Year:  2007        PMID: 17412349      PMCID: PMC2711772          DOI: 10.1016/j.jbiomech.2007.01.005

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  30 in total

1.  Inelastic strain accumulation in cortical bone during rapid transient tensile loading.

Authors:  M T Fondrk; E H Bahniuk; D T Davy
Journal:  J Biomech Eng       Date:  1999-12       Impact factor: 2.097

2.  Mineralized collagen fibrils: a mechanical model with a staggered arrangement of mineral particles.

Authors:  I Jäger; P Fratzl
Journal:  Biophys J       Date:  2000-10       Impact factor: 4.033

3.  Estimation of the poroelastic parameters of cortical bone.

Authors:  Theo H Smit; Jacques M Huyghe; Stephen C Cowin
Journal:  J Biomech       Date:  2002-06       Impact factor: 2.712

4.  Assembly of type I collagen: fusion of fibril subunits and the influence of fibril diameter on mechanical properties.

Authors:  D L Christiansen; E K Huang; F H Silver
Journal:  Matrix Biol       Date:  2000-09       Impact factor: 11.583

5.  Fatigue damage-fracture mechanics interaction in cortical bone.

Authors:  Y N Yeni; D P Fyhrie
Journal:  Bone       Date:  2002-03       Impact factor: 4.398

6.  Experimental investigation of Poisson's ratio as a damage parameter for bone fatigue.

Authors:  R M Pidaparti; A Vogt
Journal:  J Biomed Mater Res       Date:  2002-02

7.  Viscoelastic properties of bone as a function of water content.

Authors:  N Sasaki; A Enyo
Journal:  J Biomech       Date:  1995-07       Impact factor: 2.712

8.  In vivo diffuse damage in human vertebral trabecular bone.

Authors:  D Vashishth; J Koontz; S J Qiu; D Lundin-Cannon; Y N Yeni; M B Schaffler; D P Fyhrie
Journal:  Bone       Date:  2000-02       Impact factor: 4.398

9.  Relationship between damage accumulation and mechanical property degradation in cortical bone: microcrack orientation is important.

Authors:  Ozan Akkus; David F Knott; Karl J Jepsen; Dwight T Davy; Clare M Rimnac
Journal:  J Biomed Mater Res A       Date:  2003-06-15       Impact factor: 4.396

10.  Deformation behaviour and damage accumulation of cortical bone specimens from the equine tibia under cyclic loading.

Authors:  Claudia Fleck; Dietmar Eifler
Journal:  J Biomech       Date:  2003-02       Impact factor: 2.712

View more
  6 in total

1.  Variability of tissue mineral density can determine physiological creep of human vertebral cancellous bone.

Authors:  Do-Gyoon Kim; Daniel Shertok; Boon Ching Tee; Yener N Yeni
Journal:  J Biomech       Date:  2011-04-08       Impact factor: 2.712

2.  Structural and mechanical repair of diffuse damage in cortical bone in vivo.

Authors:  Zeynep Seref-Ferlengez; Jelena Basta-Pljakic; Oran D Kennedy; Claudy J Philemon; Mitchell B Schaffler
Journal:  J Bone Miner Res       Date:  2014-12       Impact factor: 6.741

3.  Near-terminal creep damage does not substantially influence fatigue life under physiological loading.

Authors:  Lorraine C Stern; Jennifer G Brinkman; Jevan Furmanski; Clare M Rimnac; Christopher J Hernandez
Journal:  J Biomech       Date:  2011-05-18       Impact factor: 2.712

4.  Systematic error in mechanical measures of damage during four-point bending fatigue of cortical bone.

Authors:  Matthew D Landrigan; Ryan K Roeder
Journal:  J Biomech       Date:  2009-04-25       Impact factor: 2.712

5.  Subrupture tendon fatigue damage.

Authors:  David T Fung; Vincent M Wang; Damien M Laudier; Jean H Shine; Jelena Basta-Pljakic; Karl J Jepsen; Mitchell B Schaffler; Evan L Flatow
Journal:  J Orthop Res       Date:  2009-02       Impact factor: 3.494

6.  Progressive post-yield behavior of human cortical bone in compression for middle-aged and elderly groups.

Authors:  Huijie Leng; X Neil Dong; Xiaodu Wang
Journal:  J Biomech       Date:  2009-01-17       Impact factor: 2.712

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.