Literature DB >> 17411409

Facemasks and aerosol delivery in vivo.

Simone Erzinger1, Karen G Schueepp, Joanne Brooks-Wildhaber, Sunalene G Devadason, Johannes H Wildhaber.   

Abstract

It has been shown in vitro that even a small air leak in the facemask can drastically reduce the efficiency of drug delivery. In addition, it has been shown that drug deposition on the face does significantly add to overall drug loss and has the potential of local side effects. The aim of this study is therefore to verify these findings in vivo. Eight asymptomatic recurrently wheezy children, aged 18-36 months, inhaled a radiolabeled salbutamol formulation either from a pressurized metered-dose inhaler through a spacer with attached facemask or from a nebulizer with attached facemask. Drug deposition of radiolabeled salbutamol was assessed with a gamma camera and expressed as a percentage of the total dose. Lung deposition expressed as a percentage of the total dose (metered dose and nebulizer fill, respectively) was 0.2% and 0.3% in children who inhaled with a non-tightly fitted facemask. Lung deposition was 0.6% and 1.4% in screaming children with a tightly fitted facemask and between 4.8% and 8.2% in patients breathing normally. Overall mask deposition was between 0.8% and 5.2%. Overall face deposition was between 2.6% and 8.4%. The results from this pilot study support the results found in in vitro studies, where a facemask leak greatly reduces drug delivery to the patient.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17411409     DOI: 10.1089/jam.2007.0572

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  11 in total

Review 1.  Measurements of deposited aerosol dose in infants and small children.

Authors:  Timothy E Corcoran
Journal:  Ann Transl Med       Date:  2021-04

2.  Aerosol Drug Delivery During Noninvasive Positive Pressure Ventilation: Effects of Intersubject Variability and Excipient Enhanced Growth.

Authors:  Ross L Walenga; P Worth Longest; Anubhav Kaviratna; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2017-01-11       Impact factor: 2.849

3.  Comparison of in vitro deposition of pharmaceutical aerosols in an idealized child throat with in vivo deposition in the upper respiratory tract of children.

Authors:  Conor A Ruzycki; Laleh Golshahi; Reinhard Vehring; Warren H Finlay
Journal:  Pharm Res       Date:  2014-01-07       Impact factor: 4.200

4.  Characterizing the Effects of Nasal Prong Interfaces on Aerosol Deposition in a Preterm Infant Nasal Model.

Authors:  Karl Bass; Mohammad A M Momin; Connor Howe; Ghali Aladwani; Sarah Strickler; Arun V Kolanjiyil; Michael Hindle; Robert M DiBlasi; Worth Longest
Journal:  AAPS PharmSciTech       Date:  2022-04-19       Impact factor: 3.246

Review 5.  Drug delivery interfaces: A way to optimize inhalation therapy in spontaneously breathing children.

Authors:  Arzu Ari
Journal:  World J Clin Pediatr       Date:  2016-08-08

Review 6.  Inhaled chemotherapy in lung cancer: future concept of nanomedicine.

Authors:  Paul Zarogoulidis; Ekaterini Chatzaki; Konstantinos Porpodis; Kalliopi Domvri; Wolfgang Hohenforst-Schmidt; Eugene P Goldberg; Nikos Karamanos; Konstantinos Zarogoulidis
Journal:  Int J Nanomedicine       Date:  2012-03-22

7.  Assessing Modeled CO(2) Retention and Rebreathing of a Facemask Designed for Efficient Delivery of Aerosols to Infants.

Authors:  Christian Mundt; Alexander Sventitskiy; Jeffrey E Cehelsky; Andrea B Patters; Markus Tservistas; Michael C Hahn; Gerd Juhl; John P Devincenzo
Journal:  ISRN Pediatr       Date:  2012-06-26

8.  The challenge of delivering therapeutic aerosols to asthma patients.

Authors:  Federico Lavorini
Journal:  ISRN Allergy       Date:  2013-08-05

Review 9.  Inhalation therapy in mechanical ventilation.

Authors:  Juçara Gasparetto Maccari; Cassiano Teixeira; Marcelo Basso Gazzana; Augusto Savi; Felippe Leopoldo Dexheimer-Neto; Marli Maria Knorst
Journal:  J Bras Pneumol       Date:  2015 Sep-Oct       Impact factor: 2.624

10.  Scintigraphic Assessment of Deposition of Radiolabeled Fluticasone Delivered from a Nebulizer and Metered Dose Inhaler in 10 Healthy Dogs.

Authors:  K E Chow; D Tyrrell; M Yang; L A Abraham; G A Anderson; C S Mansfield
Journal:  J Vet Intern Med       Date:  2017-09-29       Impact factor: 3.333

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.