Literature DB >> 17411178

Qualification of a fluorescence spectrometer for measuring true fluorescence spectra.

Paul C DeRose1, Edward A Early, Gary W Kramer.   

Abstract

New analytical methods using fluorescence detection are becoming increasingly quantitative and require easy-to-use material standards for fluorometer qualification and method validation. NIST is responding to this need by developing and producing such standards. Reported here is the first step in this process, which is to qualify a research-grade fluorescence spectrometer for measuring true fluorescence spectra of reference material candidates. "True" spectra are defined here as those with fluorescence intensity, either relative or absolute as required, and wavelength both being reported with high accuracy and known precision, after wavelength has been calibrated and corrections for excitation intensity and detection system response have been applied. The uncertainties determined in relative and absolute intensity-corrected fluorescence spectra using both calibrated source (CS)- and calibrated detector (CD)-based methods were compared. The CS-based method gave uncertainties, typically about +/-5% for relative spectral correction, that were about half that of the CD-based method for determining both relative and absolute spectral correction factors. Absolute spectral correction factors can be determined using either method without knowing the optical geometry of the instrument. The absolute spectral correction factors were found to have much larger uncertainties than the corresponding relative correction factors with uncertainties for the CS-based method of +/-10% to +/-15% being typical and +/-20% or more not being uncommon, particularly for excitation and emission wavelengths below 400 nm. Uncertainties arising from detection system nonlinearity and instrument polarization ratios were also explored.

Entities:  

Mesh:

Year:  2007        PMID: 17411178     DOI: 10.1063/1.2715952

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  3 in total

1.  Construction, figures of merit, and testing of a single-cell fluorescence excitation spectroscopy system.

Authors:  Laura S Hill; Tammi L Richardson; Luisa T M Profeta; Timothy J Shaw; Christopher J Hintz; Benjamin S Twining; Evelyn Lawrenz; Michael L Myrick
Journal:  Rev Sci Instrum       Date:  2010-01       Impact factor: 1.523

Review 2.  Advances in quantitative UV-visible spectroscopy for clinical and pre-clinical application in cancer.

Authors:  J Quincy Brown; Karthik Vishwanath; Gregory M Palmer; Nirmala Ramanujam
Journal:  Curr Opin Biotechnol       Date:  2009-03-04       Impact factor: 9.740

3.  Optical Properties of CdSe/ZnS Nanocrystals.

Authors:  Adolfas K Gaigalas; Paul DeRose; Lili Wang; Yu-Zhong Zhang
Journal:  J Res Natl Inst Stand Technol       Date:  2014-12-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.